| This document describes the method for calibrating the x, y, and z
 | |
| offsets of an "automatic z probe" in Klipper. This is useful for users
 | |
| that have a `[probe]` or `[bltouch]` section in their config file.
 | |
| 
 | |
| # Calibrating probe X and Y offsets
 | |
| 
 | |
| To calibrate the X and Y offset, navigate to the OctoPrint "Control"
 | |
| tab, home the printer, and then use the OctoPrint jogging buttons to
 | |
| move the head to a position near the center of the bed.
 | |
| 
 | |
| Place a piece of blue painters tape (or similar) on the bed underneath
 | |
| the probe. Navigate to the OctoPrint "Terminal" tab and issue a PROBE
 | |
| command:
 | |
| ```
 | |
| PROBE
 | |
| ```
 | |
| Place a mark on the tape directly under where the probe is (or use a
 | |
| similar method to note the location on the bed).
 | |
| 
 | |
| Issue a `GET_POSITION` command and record the toolhead XY location
 | |
| reported by that command. For example if one sees:
 | |
| ```
 | |
| Recv: // toolhead: X:46.500000 Y:27.000000 Z:15.000000 E:0.000000
 | |
| ```
 | |
| then one would record a probe X position of 46.5 and probe Y position
 | |
| of 27.
 | |
| 
 | |
| After recording the probe position, issue a series of G1 commands
 | |
| until the nozzle is directly above the mark on the bed. For example,
 | |
| one might issue:
 | |
| ```
 | |
| G1 F300 X57 Y30 Z15
 | |
| ```
 | |
| to move the nozzle to an X position of 57 and Y of 30. Once one finds
 | |
| the position directly above the mark, use the `GET_POSITION` command
 | |
| to report that position. This is the nozzle position.
 | |
| 
 | |
| The x_offset is then the `nozzle_x_position - probe_x_position` and
 | |
| y_offset is similarly the `nozzle_y_position - probe_y_position`.
 | |
| Update the printer.cfg file with the given values, remove the
 | |
| tape/marks from the bed, and then issue a `RESTART` command so that
 | |
| the new values take effect.
 | |
| 
 | |
| # Calibrating probe Z offset
 | |
| 
 | |
| Providing an accurate probe z_offset is critical to obtaining high
 | |
| quality prints. The z_offset is the distance between the nozzle and
 | |
| bed when the probe triggers. The Klipper `PROBE_CALIBRATE` tool can be
 | |
| used to obtain this value - it will run an automatic probe to measure
 | |
| the probe's Z trigger position and then start a manual probe to obtain
 | |
| the nozzle Z height. The probe z_offset will then be calculated from
 | |
| these measurements.
 | |
| 
 | |
| Start by homing the printer and then move the head to a position near
 | |
| the center of the bed. Navigate to the OctoPrint terminal tab and run
 | |
| the `PROBE_CALIBRATE` command to start the tool.
 | |
| 
 | |
| This tool will perform an automatic probe, then lift the head, move
 | |
| the nozzle over the location of the probe point, and start the manual
 | |
| probe tool. If the nozzle does not move to a position above the
 | |
| automatic probe point, then `ABORT` the manual probe tool and perform
 | |
| the XY probe offset calibration described above.
 | |
| 
 | |
| Once the manual probe tool starts, follow the steps described at
 | |
| ["the paper test"](Bed_Level.md#the-paper-test)) to determine the
 | |
| actual distance between the nozzle and bed at the given location. Once
 | |
| those steps are complete one can `ACCEPT` the position and save the
 | |
| results to the config file with:
 | |
| ```
 | |
| SAVE_CONFIG
 | |
| ```
 | |
| 
 | |
| Note that if a change is made to the printer's motion system, hotend
 | |
| position, or probe location then it will invalidate the results of
 | |
| PROBE_CALIBRATE.
 | |
| 
 | |
| If the probe has an X or Y offset and the bed tilt is changed (eg, by
 | |
| adjusting bed screws, running DELTA_CALIBRATE, running Z_TILT_ADJUST,
 | |
| running QUAD_GANTRY_LEVEL, or similar) then it will invalidate the
 | |
| results of PROBE_CALIBRATE. After making any of the above adjustments
 | |
| it will be necessary to run PROBE_CALIBRATE again.
 | |
| 
 | |
| If the results of PROBE_CALIBRATE are invalidated, then any previous
 | |
| [bed mesh](Bed_Mesh.md) results that were obtained using the probe are
 | |
| also invalidated - it will be necessary to rerun BED_MESH_CALIBRATE
 | |
| after recalibrating the probe.
 | |
| 
 | |
| # Repeatability check
 | |
| 
 | |
| After calibrating the probe X, Y, and Z offsets it is a good idea to
 | |
| verify that the probe provides repeatable results. Start by homing the
 | |
| printer and then move the head to a position near the center of the
 | |
| bed. Navigate to the OctoPrint terminal tab and run the
 | |
| `PROBE_ACCURACY` command.
 | |
| 
 | |
| This command will run the probe ten times and produce output similar
 | |
| to the following:
 | |
| ```
 | |
| Recv: // probe accuracy: at X:0.000 Y:0.000 Z:10.000
 | |
| Recv: // and read 10 times with speed of 5 mm/s
 | |
| Recv: // probe at -0.003,0.005 is z=2.506948
 | |
| Recv: // probe at -0.003,0.005 is z=2.519448
 | |
| Recv: // probe at -0.003,0.005 is z=2.519448
 | |
| Recv: // probe at -0.003,0.005 is z=2.506948
 | |
| Recv: // probe at -0.003,0.005 is z=2.519448
 | |
| Recv: // probe at -0.003,0.005 is z=2.519448
 | |
| Recv: // probe at -0.003,0.005 is z=2.506948
 | |
| Recv: // probe at -0.003,0.005 is z=2.506948
 | |
| Recv: // probe at -0.003,0.005 is z=2.519448
 | |
| Recv: // probe at -0.003,0.005 is z=2.506948
 | |
| Recv: // probe accuracy results: maximum 2.519448, minimum 2.506948, range 0.012500, average 2.513198, median 2.513198, standard deviation 0.006250
 | |
| ```
 | |
| 
 | |
| Ideally the tool will report an identical maximum and minimum value.
 | |
| (That is, ideally the probe obtains an identical result on all ten
 | |
| probes.) However, it's normal for the minimum and maximum values to
 | |
| differ by one Z step_distance or up to 5 microns (.005mm). The
 | |
| distance between the minimum and the maximum value is called the
 | |
| range. So, in the above example, since the printer uses a Z
 | |
| step_distance of .0125, a range of 0.012500 would be considered
 | |
| normal.
 | |
| 
 | |
| If the results of the test show a range value that is greater than 25
 | |
| microns (.025mm) then the probe does not have sufficient accuracy for
 | |
| typical bed leveling procedures. It may be possible to tune the probe
 | |
| speed and/or probe start height to improve the repeatability of the
 | |
| probe. The `PROBE_ACCURACY` command allows one to run tests with
 | |
| different parameters to see their impact - see the
 | |
| [G-Codes document](G-Codes.md) for further details. If the probe
 | |
| generally obtains repeatable results but has an occasional outlier,
 | |
| then it may be possible to account for that by using multiple samples
 | |
| on each probe - read the description of the probe `samples` config
 | |
| parameters in the [config reference](Config_Reference.md#probe) for
 | |
| more details.
 | |
| 
 | |
| If new probe speed, samples count, or other settings are needed, then
 | |
| update the printer.cfg file and issue a `RESTART` command. If so, it
 | |
| is a good idea to
 | |
| [calibrate the z_offset](#calibrating-probe-z-offset) again. If
 | |
| repeatable results can not be obtained then don't use the probe for
 | |
| bed leveling. Klipper has several manual probing tools that can be
 | |
| used instead - see the [Bed Level document](Bed_Level.md) for further
 | |
| details.
 | |
| 
 | |
| # Location Bias Check
 | |
| 
 | |
| Some probes can have a systemic bias that corrupts the results of the
 | |
| probe at certain toolhead locations. For example, if the probe mount
 | |
| tilts slightly when moving along the Y axis then it could result in
 | |
| the probe reporting biased results at different Y positions.
 | |
| 
 | |
| This is a common issue with probes on delta printers, however it can
 | |
| occur on all printers.
 | |
| 
 | |
| One can check for a location bias by using the `PROBE_CALIBRATE`
 | |
| command to measuring the probe z_offset at various X and Y locations.
 | |
| Ideally, the probe z_offset would be a constant value at every printer
 | |
| location.
 | |
| 
 | |
| For delta printers, try measuring the z_offset at a position near the
 | |
| A tower, at a position near the B tower, and at a position near the C
 | |
| tower. For cartesian, corexy, and similar printers, try measuring the
 | |
| z_offset at positions near the four corners of the bed.
 | |
| 
 | |
| Before starting this test, first calibrate the probe X, Y, and Z
 | |
| offsets as described at the beginning of this document. Then home the
 | |
| printer and navigate to the first XY position. Follow the steps at
 | |
| [calibrating probe Z offset](#calibrating-probe-z-offset) to run the
 | |
| `PROBE_CALIBRATE` command, `TESTZ` commands, and `ACCEPT` command, but
 | |
| do not run `SAVE_CONFIG`. Note the reported z_offset found. Then
 | |
| navigate to the other XY positions, repeat these `PROBE_CALIBRATE`
 | |
| steps, and note the reported z_offset.
 | |
| 
 | |
| If the difference between the minimum reported z_offset and the
 | |
| maximum reported z_offset is greater than 25 microns (.025mm) then the
 | |
| probe is not suitable for typical bed leveling procedures. See the
 | |
| [Bed Level document](Bed_Level.md) for manual probe alternatives.
 | |
| 
 | |
| # Temperature Bias
 | |
| 
 | |
| Many probes have a systemic bias when probing at different
 | |
| temperatures. For example, the probe may consistently trigger at a
 | |
| lower height when the probe is at a higher temperature.
 | |
| 
 | |
| It is recommended to run the bed leveling tools at a consistent
 | |
| temperature to account for this bias. For example, either always run
 | |
| the tools when the printer is at room temperature, or always run the
 | |
| tools after the printer has obtained a consistent print temperature.
 | |
| In either case, it is a good idea to wait several minutes after the
 | |
| desired temperature is reached, so that the printer apparatus is
 | |
| consistently at the desired temperature.
 | |
| 
 | |
| To check for a temperature bias, start with the printer at room
 | |
| temperature and then home the printer, move the head to a position
 | |
| near the center of the bed, and run the `PROBE_ACCURACY` command. Note
 | |
| the results. Then, without homing or disabling the stepper motors,
 | |
| heat the printer nozzle and bed to printing temperature, and run the
 | |
| `PROBE_ACCURACY` command again. Ideally, the command will report
 | |
| identical results. As above, if the probe does have a temperature bias
 | |
| then be careful to always use the probe at a consistent temperature.
 |