										 |  |  | This document describes the method for calibrating the x, y, and z | 
					
						
							|  |  |  | offsets of an "automatic z probe" in Klipper. This is useful for users | 
					
						
							|  |  |  | that have a `[probe]` or `[bltouch]` section in their config file. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | # Calibrating probe X and Y offsets
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | To calibrate the X and Y offset, navigate to the OctoPrint "Control" | 
					
						
							|  |  |  | tab, home the printer, and then use the OctoPrint jogging buttons to | 
					
						
							|  |  |  | move the head to a position near the center of the bed. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Place a piece of blue painters tape (or similar) on the bed underneath | 
					
						
							|  |  |  | the probe. Navigate to the OctoPrint "Terminal" tab and issue a PROBE | 
					
						
							|  |  |  | command: | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | PROBE | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | Place a mark on the tape directly under where the probe is (or use a | 
					
						
							|  |  |  | similar method to note the location on the bed). | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Issue a `GET_POSITION` command and record the toolhead XY location | 
					
						
							|  |  |  | reported by that command. For example if one sees: | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | Recv: // toolhead: X:46.500000 Y:27.000000 Z:15.000000 E:0.000000 | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | then one would record a probe X position of 46.5 and probe Y position | 
					
						
							|  |  |  | of 27. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | After recording the probe position, issue a series of G1 commands | 
					
						
							|  |  |  | until the nozzle is directly above the mark on the bed. For example, | 
					
						
							|  |  |  | one might issue: | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | G1 F300 X57 Y30 Z15 | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | to move the nozzle to an X position of 57 and Y of 30. Once one finds | 
					
						
							|  |  |  | the position directly above the mark, use the `GET_POSITION` command | 
					
						
							|  |  |  | to report that position. This is the nozzle position. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The x_offset is then the `nozzle_x_position - probe_x_position` and | 
					
						
							|  |  |  | y_offset is similarly the `nozzle_y_position - probe_y_position`. | 
					
						
							|  |  |  | Update the printer.cfg file with the given values, remove the | 
					
						
							|  |  |  | tape/marks from the bed, and then issue a `RESTART` command so that | 
					
						
							|  |  |  | the new values take effect. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | # Calibrating probe Z offset
 | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2019-06-03 10:51:58 -04:00
										 |  |  | Providing an accurate probe z_offset is critical to obtaining high | 
					
						
							|  |  |  | quality prints. The z_offset is the distance between the nozzle and | 
					
						
							|  |  |  | bed when the probe triggers. The Klipper `PROBE_CALIBRATE` tool can be | 
					
						
							|  |  |  | used to obtain this value - it will run an automatic probe to measure | 
					
						
							|  |  |  | the probe's Z trigger position and then start a manual probe to obtain | 
					
						
							|  |  |  | the nozzle Z height. The probe z_offset will then be calculated from | 
					
						
							|  |  |  | these measurements. | 
					
						
							| 
									
										
										
										
											2019-02-06 18:49:11 -05:00
										 |  |  | 
 | 
					
						
							|  |  |  | Start by homing the printer and then move the head to a position near | 
					
						
							|  |  |  | the center of the bed. Navigate to the OctoPrint terminal tab and run | 
					
						
							| 
									
										
										
										
											2019-06-03 10:51:58 -04:00
										 |  |  | the `PROBE_CALIBRATE` command to start the tool. | 
					
						
							| 
									
										
										
										
											2019-02-06 18:49:11 -05:00
										 |  |  | 
 | 
					
						
							|  |  |  | This tool will perform an automatic probe, then lift the head, move | 
					
						
							|  |  |  | the nozzle over the location of the probe point, and start the manual | 
					
						
							| 
									
										
										
										
											2019-05-24 22:34:24 -04:00
										 |  |  | probe tool. If the nozzle does not move to a position above the | 
					
						
							|  |  |  | automatic probe point, then `ABORT` the manual probe tool and perform | 
					
						
							|  |  |  | the XY probe offset calibration described above. | 
					
						
							| 
									
										
										
										
											2019-02-06 18:49:11 -05:00
										 |  |  | 
 | 
					
						
							| 
									
										
										
										
											2019-05-24 22:34:24 -04:00
										 |  |  | Once the manual probe tool starts, follow the steps described at | 
					
						
							|  |  |  | ["the paper test"](Bed_Level.md#the-paper-test)) to determine the | 
					
						
							|  |  |  | actual distance between the nozzle and bed at the given location. Once | 
					
						
							|  |  |  | those steps are complete one can `ACCEPT` the position and save the | 
					
						
							|  |  |  | results to the config file with: | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | SAVE_CONFIG | 
					
						
							|  |  |  | ``` | 
					
						
							| 
									
										
										
										
											2019-06-03 10:51:58 -04:00
										 |  |  | 
 | 
					
						
							| 
									
										
										
										
											2020-10-17 19:36:45 -04:00
										 |  |  | Note that if a change is made to the printer's motion system, hotend | 
					
						
							|  |  |  | position, or probe location then it will invalidate the results of | 
					
						
							|  |  |  | PROBE_CALIBRATE. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | If the probe has an X or Y offset and the bed tilt is changed (eg, by | 
					
						
							|  |  |  | adjusting bed screws, running DELTA_CALIBRATE, running Z_TILT_ADJUST, | 
					
						
							|  |  |  | running QUAD_GANTRY_LEVEL, or similar) then it will invalidate the | 
					
						
							|  |  |  | results of PROBE_CALIBRATE. After making any of the above adjustments | 
					
						
							|  |  |  | it will be necessary to run PROBE_CALIBRATE again. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | If the results of PROBE_CALIBRATE are invalidated, then any previous | 
					
						
							|  |  |  | [bed mesh](Bed_Mesh.md) results that were obtained using the probe are | 
					
						
							|  |  |  | also invalidated - it will be necessary to rerun BED_MESH_CALIBRATE | 
					
						
							|  |  |  | after recalibrating the probe. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2019-06-03 10:51:58 -04:00
										 |  |  | # Repeatability check
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | After calibrating the probe X, Y, and Z offsets it is a good idea to | 
					
						
							|  |  |  | verify that the probe provides repeatable results. Start by homing the | 
					
						
							|  |  |  | printer and then move the head to a position near the center of the | 
					
						
							|  |  |  | bed. Navigate to the OctoPrint terminal tab and run the | 
					
						
							|  |  |  | `PROBE_ACCURACY` command. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | This command will run the probe ten times and produce output similar | 
					
						
							|  |  |  | to the following: | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | Recv: // probe accuracy: at X:0.000 Y:0.000 Z:10.000 | 
					
						
							|  |  |  | Recv: // and read 10 times with speed of 5 mm/s | 
					
						
							|  |  |  | Recv: // probe at -0.003,0.005 is z=2.506948 | 
					
						
							|  |  |  | Recv: // probe at -0.003,0.005 is z=2.519448 | 
					
						
							|  |  |  | Recv: // probe at -0.003,0.005 is z=2.519448 | 
					
						
							|  |  |  | Recv: // probe at -0.003,0.005 is z=2.506948 | 
					
						
							|  |  |  | Recv: // probe at -0.003,0.005 is z=2.519448 | 
					
						
							|  |  |  | Recv: // probe at -0.003,0.005 is z=2.519448 | 
					
						
							|  |  |  | Recv: // probe at -0.003,0.005 is z=2.506948 | 
					
						
							|  |  |  | Recv: // probe at -0.003,0.005 is z=2.506948 | 
					
						
							|  |  |  | Recv: // probe at -0.003,0.005 is z=2.519448 | 
					
						
							|  |  |  | Recv: // probe at -0.003,0.005 is z=2.506948 | 
					
						
							| 
									
										
										
										
											2019-09-29 22:56:46 +02:00
										 |  |  | Recv: // probe accuracy results: maximum 2.519448, minimum 2.506948, range 0.012500, average 2.513198, median 2.513198, standard deviation 0.006250 | 
					
						
							| 
									
										
										
										
											2019-06-03 10:51:58 -04:00
										 |  |  | ``` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Ideally the tool will report an identical maximum and minimum value. | 
					
						
							|  |  |  | (That is, ideally the probe obtains an identical result on all ten | 
					
						
							| 
									
										
										
										
											2020-10-17 18:48:43 -04:00
										 |  |  | probes.) However, it's normal for the minimum and maximum values to | 
					
						
							|  |  |  | differ by one Z step_distance or up to 5 microns (.005mm). The | 
					
						
							|  |  |  | distance between the minimum and the maximum value is called the | 
					
						
							|  |  |  | range. So, in the above example, since the printer uses a Z | 
					
						
							|  |  |  | step_distance of .0125, a range of 0.012500 would be considered | 
					
						
							|  |  |  | normal. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | If the results of the test show a range value that is greater than 25 | 
					
						
							|  |  |  | microns (.025mm) then the probe does not have sufficient accuracy for | 
					
						
							|  |  |  | typical bed leveling procedures. It may be possible to tune the probe | 
					
						
							|  |  |  | speed and/or probe start height to improve the repeatability of the | 
					
						
							|  |  |  | probe. The `PROBE_ACCURACY` command allows one to run tests with | 
					
						
							|  |  |  | different parameters to see their impact - see the | 
					
						
							|  |  |  | [G-Codes document](G-Codes.md) for further details. If the probe | 
					
						
							| 
									
										
										
										
											2019-06-03 10:51:58 -04:00
										 |  |  | generally obtains repeatable results but has an occasional outlier, | 
					
						
							|  |  |  | then it may be possible to account for that by using multiple samples | 
					
						
							|  |  |  | on each probe - read the description of the probe `samples` config | 
					
						
							| 
									
										
										
										
											2020-11-16 18:47:32 -05:00
										 |  |  | parameters in the [config reference](Config_Reference.md#probe) for | 
					
						
							|  |  |  | more details. | 
					
						
							| 
									
										
										
										
											2019-06-03 10:51:58 -04:00
										 |  |  | 
 | 
					
						
							|  |  |  | If new probe speed, samples count, or other settings are needed, then | 
					
						
							|  |  |  | update the printer.cfg file and issue a `RESTART` command. If so, it | 
					
						
							|  |  |  | is a good idea to | 
					
						
							|  |  |  | [calibrate the z_offset](#calibrating-probe-z-offset) again. If | 
					
						
							|  |  |  | repeatable results can not be obtained then don't use the probe for | 
					
						
							|  |  |  | bed leveling. Klipper has several manual probing tools that can be | 
					
						
							|  |  |  | used instead - see the [Bed Level document](Bed_Level.md) for further | 
					
						
							|  |  |  | details. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | # Location Bias Check
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Some probes can have a systemic bias that corrupts the results of the | 
					
						
							|  |  |  | probe at certain toolhead locations. For example, if the probe mount | 
					
						
							|  |  |  | tilts slightly when moving along the Y axis then it could result in | 
					
						
							|  |  |  | the probe reporting biased results at different Y positions. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | This is a common issue with probes on delta printers, however it can | 
					
						
							|  |  |  | occur on all printers. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | One can check for a location bias by using the `PROBE_CALIBRATE` | 
					
						
							| 
									
										
										
										
											2020-10-17 18:48:43 -04:00
										 |  |  | command to measuring the probe z_offset at various X and Y locations. | 
					
						
							|  |  |  | Ideally, the probe z_offset would be a constant value at every printer | 
					
						
							|  |  |  | location. | 
					
						
							| 
									
										
										
										
											2019-06-03 10:51:58 -04:00
										 |  |  | 
 | 
					
						
							|  |  |  | For delta printers, try measuring the z_offset at a position near the | 
					
						
							|  |  |  | A tower, at a position near the B tower, and at a position near the C | 
					
						
							|  |  |  | tower. For cartesian, corexy, and similar printers, try measuring the | 
					
						
							|  |  |  | z_offset at positions near the four corners of the bed. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Before starting this test, first calibrate the probe X, Y, and Z | 
					
						
							|  |  |  | offsets as described at the beginning of this document. Then home the | 
					
						
							|  |  |  | printer and navigate to the first XY position. Follow the steps at | 
					
						
							|  |  |  | [calibrating probe Z offset](#calibrating-probe-z-offset) to run the | 
					
						
							|  |  |  | `PROBE_CALIBRATE` command, `TESTZ` commands, and `ACCEPT` command, but | 
					
						
							|  |  |  | do not run `SAVE_CONFIG`. Note the reported z_offset found. Then | 
					
						
							|  |  |  | navigate to the other XY positions, repeat these `PROBE_CALIBRATE` | 
					
						
							|  |  |  | steps, and note the reported z_offset. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | If the difference between the minimum reported z_offset and the | 
					
						
							|  |  |  | maximum reported z_offset is greater than 25 microns (.025mm) then the | 
					
						
							|  |  |  | probe is not suitable for typical bed leveling procedures. See the | 
					
						
							|  |  |  | [Bed Level document](Bed_Level.md) for manual probe alternatives. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | # Temperature Bias
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Many probes have a systemic bias when probing at different | 
					
						
							|  |  |  | temperatures. For example, the probe may consistently trigger at a | 
					
						
							|  |  |  | lower height when the probe is at a higher temperature. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | It is recommended to run the bed leveling tools at a consistent | 
					
						
							|  |  |  | temperature to account for this bias. For example, either always run | 
					
						
							|  |  |  | the tools when the printer is at room temperature, or always run the | 
					
						
							|  |  |  | tools after the printer has obtained a consistent print temperature. | 
					
						
							|  |  |  | In either case, it is a good idea to wait several minutes after the | 
					
						
							|  |  |  | desired temperature is reached, so that the printer apparatus is | 
					
						
							|  |  |  | consistently at the desired temperature. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | To check for a temperature bias, start with the printer at room | 
					
						
							|  |  |  | temperature and then home the printer, move the head to a position | 
					
						
							|  |  |  | near the center of the bed, and run the `PROBE_ACCURACY` command. Note | 
					
						
							|  |  |  | the results. Then, without homing or disabling the stepper motors, | 
					
						
							|  |  |  | heat the printer nozzle and bed to printing temperature, and run the | 
					
						
							|  |  |  | `PROBE_ACCURACY` command again. Ideally, the command will report | 
					
						
							|  |  |  | identical results. As above, if the probe does have a temperature bias | 
					
						
							|  |  |  | then be careful to always use the probe at a consistent temperature. |