| This document describes the protocol Klipper uses to communicate over
 | |
| [CAN bus](https://en.wikipedia.org/wiki/CAN_bus). See
 | |
| [CANBUS.md](CANBUS.md) for information on configuring Klipper with CAN
 | |
| bus.
 | |
| 
 | |
| # Micro-controller id assignment
 | |
| 
 | |
| Klipper uses only CAN 2.0A standard size CAN bus packets, which are
 | |
| limited to 8 data bytes and an 11-bit CAN bus identifier. In order to
 | |
| support efficient communication, each micro-controller is assigned at
 | |
| run-time a unique 1-byte CAN bus nodeid (`canbus_nodeid`) for general
 | |
| Klipper command and response traffic. Klipper command messages going
 | |
| from host to micro-controller use the CAN bus id of `canbus_nodeid *
 | |
| 2 + 256`, while Klipper response messages from micro-controller to
 | |
| host use `canbus_nodeid * 2 + 256 + 1`.
 | |
| 
 | |
| Each micro-controller has a factory assigned unique chip identifier
 | |
| that is used during id assignment. This identifier can exceed the
 | |
| length of one CAN packet, so a hash function is used to generate a
 | |
| unique 6-byte id (`canbus_uuid`) from the factory id.
 | |
| 
 | |
| # Admin messages
 | |
| 
 | |
| Admin messages are used for id assignment. Admin messages sent from
 | |
| host to micro-controller use the CAN bus id `0x3f0` and messages sent
 | |
| from micro-controller to host use the CAN bus id `0x3f1`. All
 | |
| micro-controllers listen to messages on id `0x3f0`; that id can be
 | |
| thought of as a "broadcast address".
 | |
| 
 | |
| ## CMD_QUERY_UNASSIGNED message
 | |
| 
 | |
| This command queries all micro-controllers that have not yet been
 | |
| assigned a `canbus_nodeid`. Unassigned micro-controllers will respond
 | |
| with a RESP_NEED_NODEID response message.
 | |
| 
 | |
| The CMD_QUERY_UNASSIGNED message format is:
 | |
| `<1-byte message_id = 0x00>`
 | |
| 
 | |
| ## CMD_SET_NODEID message
 | |
| 
 | |
| This command assigns a `canbus_nodeid` to the micro-controller with a
 | |
| given `canbus_uuid`.
 | |
| 
 | |
| The CMD_SET_NODEID message format is:
 | |
| `<1-byte message_id = 0x01><6-byte canbus_uuid><1-byte canbus_nodeid>`
 | |
| 
 | |
| ## RESP_NEED_NODEID message
 | |
| 
 | |
| The RESP_NEED_NODEID message format is:
 | |
| `<1-byte message_id = 0x20><6-byte canbus_uuid>`
 | |
| 
 | |
| # Data Packets
 | |
| 
 | |
| A micro-controller that has been assigned a nodeid via the
 | |
| CMD_SET_NODEID command can send and receive data packets.
 | |
| 
 | |
| The packet data in messages using the node's receive CAN bus id
 | |
| (`canbus_nodeid * 2 + 256`) are simply appended to a buffer, and when
 | |
| a complete [mcu protocol message](Protocol.md) is found its contents
 | |
| are parsed and processed. The data is treated as a byte stream - there
 | |
| is no requirement for the start of a Klipper message block to align
 | |
| with the start of a CAN bus packet.
 | |
| 
 | |
| Similarly, mcu protocol message responses are sent from
 | |
| micro-controller to host by copying the message data into one or more
 | |
| packets with the node's transmit CAN bus id (`canbus_nodeid * 2 +
 | |
| 256 + 1`).
 |