											2021-02-07 15:23:19 -05:00
										 |  |  | This document describes the protocol Klipper uses to communicate over | 
					
						
							| 
									
										
										
										
											2021-03-04 12:51:13 -05:00
										 |  |  | [CAN bus](https://en.wikipedia.org/wiki/CAN_bus). See | 
					
						
							|  |  |  | [CANBUS.md](CANBUS.md) for information on configuring Klipper with CAN | 
					
						
							|  |  |  | bus. | 
					
						
							| 
									
										
										
										
											2021-02-07 15:23:19 -05:00
										 |  |  | 
 | 
					
						
							|  |  |  | # Micro-controller id assignment
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Klipper uses only CAN 2.0A standard size CAN bus packets, which are | 
					
						
							|  |  |  | limited to 8 data bytes and an 11-bit CAN bus identifier. In order to | 
					
						
							|  |  |  | support efficient communication, each micro-controller is assigned at | 
					
						
							|  |  |  | run-time a unique 1-byte CAN bus nodeid (`canbus_nodeid`) for general | 
					
						
							|  |  |  | Klipper command and response traffic. Klipper command messages going | 
					
						
							|  |  |  | from host to micro-controller use the CAN bus id of `canbus_nodeid * | 
					
						
							|  |  |  | 2 + 256`, while Klipper response messages from micro-controller to | 
					
						
							|  |  |  | host use `canbus_nodeid * 2 + 256 + 1`. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Each micro-controller has a factory assigned unique chip identifier | 
					
						
							|  |  |  | that is used during id assignment. This identifier can exceed the | 
					
						
							|  |  |  | length of one CAN packet, so a hash function is used to generate a | 
					
						
							|  |  |  | unique 6-byte id (`canbus_uuid`) from the factory id. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | # Admin messages
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Admin messages are used for id assignment. Admin messages sent from | 
					
						
							|  |  |  | host to micro-controller use the CAN bus id `0x3f0` and messages sent | 
					
						
							|  |  |  | from micro-controller to host use the CAN bus id `0x3f1`. All | 
					
						
							|  |  |  | micro-controllers listen to messages on id `0x3f0`; that id can be | 
					
						
							|  |  |  | thought of as a "broadcast address". | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## CMD_QUERY_UNASSIGNED message
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | This command queries all micro-controllers that have not yet been | 
					
						
							|  |  |  | assigned a `canbus_nodeid`. Unassigned micro-controllers will respond | 
					
						
							|  |  |  | with a RESP_NEED_NODEID response message. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The CMD_QUERY_UNASSIGNED message format is: | 
					
						
							|  |  |  | `<1-byte message_id = 0x00>` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## CMD_SET_NODEID message
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | This command assigns a `canbus_nodeid` to the micro-controller with a | 
					
						
							|  |  |  | given `canbus_uuid`. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The CMD_SET_NODEID message format is: | 
					
						
							|  |  |  | `<1-byte message_id = 0x01><6-byte canbus_uuid><1-byte canbus_nodeid>` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## RESP_NEED_NODEID message
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The RESP_NEED_NODEID message format is: | 
					
						
							|  |  |  | `<1-byte message_id = 0x20><6-byte canbus_uuid>` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | # Data Packets
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | A micro-controller that has been assigned a nodeid via the | 
					
						
							|  |  |  | CMD_SET_NODEID command can send and receive data packets. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The packet data in messages using the node's receive CAN bus id | 
					
						
							|  |  |  | (`canbus_nodeid * 2 + 256`) are simply appended to a buffer, and when | 
					
						
							|  |  |  | a complete [mcu protocol message](Protocol.md) is found its contents | 
					
						
							|  |  |  | are parsed and processed. The data is treated as a byte stream - there | 
					
						
							|  |  |  | is no requirement for the start of a Klipper message block to align | 
					
						
							|  |  |  | with the start of a CAN bus packet. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Similarly, mcu protocol message responses are sent from | 
					
						
							|  |  |  | micro-controller to host by copying the message data into one or more | 
					
						
							|  |  |  | packets with the node's transmit CAN bus id (`canbus_nodeid * 2 + | 
					
						
							|  |  |  | 256 + 1`). |