| This document provides a list of steps to help confirm the pin
 | |
| settings in the Klipper printer.cfg file.  It is a good idea to run
 | |
| through these steps after following the steps in the
 | |
| [installation document](Installation.md).
 | |
| 
 | |
| During this guide, it may be necessary to make changes to the Klipper
 | |
| config file. Be sure to issue a RESTART command after every change to
 | |
| the config file to ensure that the change takes effect (type "restart"
 | |
| in the Octoprint terminal tab and then click "Send"). It's also a good
 | |
| idea to issue a STATUS command after every RESTART to verify that the
 | |
| config file is successfully loaded.
 | |
| 
 | |
| ### Verify temperature
 | |
| 
 | |
| Start by verifying that temperatures are being properly reported.
 | |
| Navigate to the Octoprint temperature tab.
 | |
| 
 | |
| 
 | |
| 
 | |
| Verify that the temperature of the nozzle and bed (if applicable) are
 | |
| present and not increasing. If it is increasing, remove power from the
 | |
| printer. If the temperatures are not accurate, review the
 | |
| "sensor_type" and "sensor_pin" settings for the nozzle and/or bed.
 | |
| 
 | |
| ### Verify M112
 | |
| 
 | |
| Navigate to the Octoprint terminal tab and issue an M112 command in
 | |
| the terminal box. This command requests Klipper to go into a
 | |
| "shutdown" state. It will cause Octoprint to disconnect from Klipper -
 | |
| navigate to the Connection area and click on "Connect" to cause
 | |
| Octoprint to reconnect. Then navigate to the Octoprint temperature tab
 | |
| and verify that temperatures continue to update and the temperatures
 | |
| are not increasing. If temperatures are increasing, remove power from
 | |
| the printer.
 | |
| 
 | |
| The M112 command causes Klipper to go into a "shutdown" state. To
 | |
| clear this state, issue a FIRMWARE_RESTART command in the Octoprint
 | |
| terminal tab.
 | |
| 
 | |
| ### Verify heaters
 | |
| 
 | |
| Navigate to the Octoprint temperature tab and type in 50 followed by
 | |
| enter in the "Tool" temperature box. The extruder temperature in the
 | |
| graph should start to increase (within about 30 seconds or so). Then
 | |
| go to the "Tool" temperature drop-down box and select "Off". After
 | |
| several minutes the temperature should start to return to its initial
 | |
| room temperature value. If the temperature does not increase then
 | |
| verify the "heater_pin" setting in the config.
 | |
| 
 | |
| If the printer has a heated bed then perform the above test again with
 | |
| the bed.
 | |
| 
 | |
| ### Verify stepper motor enable pin
 | |
| 
 | |
| Verify that all of the printer axes can manually move freely (the
 | |
| stepper motors are disabled). If not, issue an M84 command to disable
 | |
| the motors. If any of the axes still can not move freely, then verify
 | |
| the stepper "enable_pin" configuration for the given axis. On most
 | |
| commodity stepper motor drivers, the motor enable pin is "active low"
 | |
| and therefore the enable pin should have a "!" before the pin (for
 | |
| example, "enable_pin: !ar38").
 | |
| 
 | |
| ### Verify endstops
 | |
| 
 | |
| Manually move all the printer axes so that none of them are in contact
 | |
| with an endstop. Send a QUERY_ENDSTOPS command via the Octoprint
 | |
| terminal tab. It should respond with the current state of all of the
 | |
| configured endstops and they should all report a state of "open". For
 | |
| each of the endstops, rerun the QUERY_ENDSTOPS command while manually
 | |
| triggering the endstop. The QUERY_ENDSTOPS command should report the
 | |
| endstop as "TRIGGERED".
 | |
| 
 | |
| If the endstop appears inverted (it reports "open" when triggered and
 | |
| vice-versa) then add a "!" to the pin definition (for example,
 | |
| "endstop_pin: ^!ar3"), or remove the "!" if there is already one
 | |
| present.
 | |
| 
 | |
| If the endstop does not change at all then it generally indicates that
 | |
| the endstop is connected to a different pin. However, it may also
 | |
| require a change to the pullup setting of the pin (the '^' at the
 | |
| start of the endstop_pin name - most printers will use a pullup
 | |
| resistor and the '^' should be present).
 | |
| 
 | |
| ### Verify stepper motors
 | |
| 
 | |
| Use the STEPPER_BUZZ command to verify the connectivity of each
 | |
| stepper motor. Start by manually positioning the given axis to a
 | |
| midway point and then run `STEPPER_BUZZ STEPPER=stepper_x`. The
 | |
| STEPPER_BUZZ command will cause the given stepper to move one
 | |
| millimeter in a positive direction and then it will return to its
 | |
| starting position. (If the endstop is defined at position_endstop=0
 | |
| then at the start of each movement the stepper will move away from the
 | |
| endstop.) It will perform this oscillation ten times.
 | |
| 
 | |
| If the stepper does not move at all, then verify the "enable_pin" and
 | |
| "step_pin" settings for the stepper. If the stepper motor moves but
 | |
| does not return to its original position then verify the "dir_pin"
 | |
| setting. If the stepper motor oscillates in an incorrect direction,
 | |
| then it generally indicates that the "dir_pin" for the axis needs to
 | |
| be inverted. This is done by adding a '!' to the "dir_pin" in the
 | |
| printer config file (or removing it if one is already there). If the
 | |
| motor moves significantly more or significantly less than one
 | |
| millimeter then verify the "step_distance" setting.
 | |
| 
 | |
| Run the above test for each stepper motor defined in the config
 | |
| file. (Set the STEPPER parameter of the STEPPER_BUZZ command to the
 | |
| name of the config section that is to be tested.) If there is no
 | |
| filament in the extruder then one can use STEPPER_BUZZ to verify the
 | |
| extruder motor connectivity (use STEPPER=extruder). Otherwise, it's
 | |
| best to test the extruder motor separately (see the next section).
 | |
| 
 | |
| After verifying all endstops and verifying all stepper motors the
 | |
| homing mechanism should be tested. Issue a G28 command to home all
 | |
| axes.  Remove power from the printer if it does not home properly.
 | |
| Rerun the endstop and stepper motor verification steps if necessary.
 | |
| 
 | |
| ### Verify extruder motor
 | |
| 
 | |
| To test the extruder motor it will be necessary to heat the extruder
 | |
| to a printing temperature. Navigate to the Octoprint temperature tab
 | |
| and select a target temperature from the temperature drop-down box (or
 | |
| manually enter an appropriate temperature). Wait for the printer to
 | |
| reach the desired temperature. Then navigate to the Octoprint control
 | |
| tab and click the "Extrude" button. Verify that the extruder motor
 | |
| turns in the correct direction. If it does not, see the
 | |
| troubleshooting tips in the previous section to confirm the
 | |
| "enable_pin", "step_pin", and "dir_pin" settings for the extruder.
 | |
| 
 | |
| ### Calibrate PID settings
 | |
| 
 | |
| Klipper supports
 | |
| [PID control](https://en.wikipedia.org/wiki/PID_controller) for the
 | |
| extruder and bed heaters. In order to use this control mechanism it is
 | |
| necessary to calibrate the PID settings on each printer. (PID settings
 | |
| found in other firmwares or in the example configuration files often
 | |
| work poorly.)
 | |
| 
 | |
| To calibrate the extruder, navigate to the OctoPrint terminal tab and
 | |
| run the PID_CALIBRATE command. For example: `PID_CALIBRATE
 | |
| HEATER=extruder TARGET=170`
 | |
| 
 | |
| At the completion of the tuning test run `SAVE_CONFIG` to update the
 | |
| printer.cfg file the new PID settings.
 | |
| 
 | |
| If the printer has a heated bed and it supports being driven by PWM
 | |
| (Pulse Width Modulation) then it is recommended to use PID control for
 | |
| the bed. (When the bed heater is controlled using the PID algorithm it
 | |
| may turn on and off ten times a second, which may not be suitable for
 | |
| heaters using a mechanical switch.) A typical bed PID calibration
 | |
| command is: `PID_CALIBRATE HEATER=heater_bed TARGET=60`
 | |
| 
 | |
| ### Next steps
 | |
| 
 | |
| This guide is intended to help with basic verification of pin settings
 | |
| in the Klipper configuration file. Be sure to read the
 | |
| [bed leveling](Bed_Level.md) guide. Also see the [Slicers](Slicers.md)
 | |
| document for information on configuring a slicer with Klipper.
 | |
| 
 | |
| After one has verified that basic printing works, it is a good idea to
 | |
| consider calibrating [pressure advance](Pressure_Advance.md).
 | |
| 
 | |
| It may be necessary to perform other types of detailed printer
 | |
| calibration - a number of guides are available online to help with
 | |
| this (for example, do a web search for "3d printer calibration").
 | |
| As an example, if you experience the effect called ringing,
 | |
| you may try following [resonance compensation](Resonance_Compensation.md)
 | |
| tuning guide.
 |