| Connecting BL-Touch
 | |
| ===================
 | |
| 
 | |
| A **warning** before you start: Avoid touching the BL-Touch pin with
 | |
| your bare fingers, since it is quite sensitive to finger grease. And
 | |
| if you do touch it, be very gentle, in order to not bend or push
 | |
| anything.
 | |
| 
 | |
| Hook up the BL-Touch "servo" connector to a `control_pin` according to
 | |
| the BL-Touch documentation or your MCU documentation. Using the
 | |
| original wiring, the yellow wire from the triple is the `control_pin`
 | |
| and the white wire from the pair is the `sensor_pin`. You need to
 | |
| configure these pins according to your wiring. For example:
 | |
| 
 | |
| ```
 | |
| [bltouch]
 | |
| sensor_pin: P1.24
 | |
| control_pin: P1.26
 | |
| ```
 | |
| 
 | |
| If the BL-Touch will be used to home the Z axis then set `endstop_pin:
 | |
| probe:z_virtual_endstop` in the `[stepper_z]` config section and add a
 | |
| `[safe_z_home]` config section to raise the z axis, home the xy axes,
 | |
| move to the center of the bed, and home the z axis. For example:
 | |
| 
 | |
| ```
 | |
| [safe_z_home]
 | |
| home_xy_position: 100,100 # Change coordinates to the center of your print bed
 | |
| speed: 50
 | |
| z_hop: 10                 # Move up 10mm
 | |
| z_hop_speed: 5
 | |
| ```
 | |
| 
 | |
| It's important that the z_hop movement in safe_z_home is high enough
 | |
| that the probe doesn't hit anything even if the probe pin happens to
 | |
| be in its lowest state.
 | |
| 
 | |
| Initial tests
 | |
| =============
 | |
| 
 | |
| Before moving on, verify that the BL-Touch is mounted at the correct
 | |
| height, the pin should be roughly 2 mm above the nozzle when retracted
 | |
| 
 | |
| When you turn on the printer, the BL-Touch probe should perform a
 | |
| self-test and move the pin up and down a couple of times. Once the
 | |
| self-test is completed, the pin should be retracted and the red LED on
 | |
| the probe should be lit. If there are any errors, for example the
 | |
| probe is flashing red or the pin is down instead of up, please turn
 | |
| off the printer and check the wiring and configuration.
 | |
| 
 | |
| If the above is looking good, it's time to test that the control pin
 | |
| is working correctly. First run `BLTOUCH_DEBUG COMMAND=pin_down` in
 | |
| your printer terminal. Verify that the pin moves down and that the red
 | |
| LED on the probe turns off. If not, check your wiring and
 | |
| configuration again. Next issue a `BLTOUCH_DEBUG COMMAND=pin_up`,
 | |
| verify that the pin moves up, and that the red light turns on
 | |
| again. If it's flashing then there's some problem.
 | |
| 
 | |
| The next step is to confirm that the sensor pin is working correctly.
 | |
| Run `BLTOUCH_DEBUG COMMAND=pin_down`, verify that the pin moves down,
 | |
| run `BLTOUCH_DEBUG COMMAND=touch_mode`, run `QUERY_PROBE`, and verify
 | |
| that command reports "probe: open". Then while gently pushing the pin
 | |
| up slightly with the nail of your finger run `QUERY_PROBE` again.
 | |
| Verify the command reports "probe: TRIGGERED". If either query does
 | |
| not report the correct message then check your wiring and
 | |
| configuration again. At the completion of this test run `BLTOUCH_DEBUG
 | |
| COMMAND=pin_up` and verify that the pin moves up.
 | |
| 
 | |
| After completing the BL-Touch control pin and sensor pin tests, it is
 | |
| now time to test probing, but with a twist. Instead of letting the
 | |
| probe pin touch the print bed, let it touch the nail on your finger.
 | |
| Position the toolhead far from the bed, issue a `G28` (or `PROBE` if
 | |
| not using probe:z_virtual_endstop), wait until the toolhead starts to
 | |
| move down, and stop the movement by very gently touching the pin with
 | |
| your nail. You may have to do it twice, since the default homing
 | |
| configuration probes twice. Be prepared to turn off the printer if it
 | |
| doesn't stop when you touch the pin.
 | |
| 
 | |
| If that was successful, do another `G28` (or `PROBE`) but this time
 | |
| let it touch the bed as it should.
 | |
| 
 | |
| BL-Touch gone bad
 | |
| =================
 | |
| 
 | |
| Once the BL-Touch is in inconsistent state, it starts blinking red.
 | |
| You can force it to leave that state by issuing:
 | |
| 
 | |
|  BLTOUCH_DEBUG COMMAND=reset
 | |
| 
 | |
| This may happen if its calibration is interrupted by the probe being
 | |
| blocked from being extracted.
 | |
| 
 | |
| However, the BL-Touch may also not be able to calibrate itself
 | |
| anymore. This happens if the screw on its top is in the wrong position
 | |
| or the magnetic core inside the probe pin has moved. If it has moved
 | |
| up so that it sticks to the screw, it may not be able to lower its pin
 | |
| anymore. With this behavior you need to open the screw and use a
 | |
| ball-point pen to push it gently back into place. Re-Insert the pin
 | |
| into the BL-Touch so that it falls into the extracted position.
 | |
| Carefully readjust the headless screw into place. You need to find the
 | |
| right position so it is able to lower and raise the pin and the red
 | |
| light turns on and of. Use the `reset`, `pin_up` and `pin_down`
 | |
| commands to achieve this.
 | |
| 
 | |
| BL-Touch "clones"
 | |
| =================
 | |
| 
 | |
| Many BL-Touch "clone" devices work correctly with Klipper using the
 | |
| default configuration. However, some "clone" devices may require
 | |
| configuration of `pin_up_reports_not_triggered` or
 | |
| `pin_up_touch_mode_reports_triggered`.
 | |
| 
 | |
| Important! Do not configure `pin_up_reports_not_triggered` or
 | |
| `pin_up_touch_mode_reports_triggered` to False without first following
 | |
| these directions. Do not configure either of these to False on a
 | |
| genuine BL-Touch. Incorrectly setting these to False can increase
 | |
| probing time and can increase the risk of damaging the printer.
 | |
| 
 | |
| Some "clone" devices are unable to perform Klipper's internal sensor
 | |
| verification test. On these devices, attempts to home or probe can
 | |
| result in Klipper reporting a "BLTouch failed to verify sensor state"
 | |
| error. If this occurs, then manually run the steps to confirm the
 | |
| sensor pin is working as described in the
 | |
| [initial tests section](#initial-tests). If the `QUERY_PROBE` commands
 | |
| in that test always produce the expected results and "BLTouch failed
 | |
| to verify sensor state" errors still occur, then it may be necessary
 | |
| to set `pin_up_touch_mode_reports_triggered` to False in the Klipper
 | |
| config file.
 | |
| 
 | |
| A rare number of old "clone" devices are unable to report when they
 | |
| have successfully raised their probe. On these devices Klipper will
 | |
| report a "BLTouch failed to raise probe" error after every home or
 | |
| probe attempt. One can test for these devices - move the head far from
 | |
| the bed, run `BLTOUCH_DEBUG COMMAND=pin_down`, verify the pin has
 | |
| moved down, run `QUERY_PROBE`, verify that command reports "probe:
 | |
| open", run `BLTOUCH_DEBUG COMMAND=pin_up`, verify the pin has moved
 | |
| up, and run `QUERY_PROBE`. If the pin remains up, the device does not
 | |
| enter an error state, and the first query reports "probe: open" while
 | |
| the second query reports "probe: TRIGGERED" then it indicates that
 | |
| `pin_up_reports_not_triggered` should be set to False in the Klipper
 | |
| config file.
 | |
| 
 | |
| BL-Touch v3
 | |
| ===========
 | |
| 
 | |
| Some BL-Touch v3.0 and BL-Touch 3.1 devices may require configuring
 | |
| `probe_with_touch_mode` in the printer config file.
 | |
| 
 | |
| If the BL-Touch v3.0 has its signal wire connected to an endstop pin
 | |
| (with a noise filtering capacitor), then the BL-Touch v3.0 may not be
 | |
| able to consistently send a signal during homing and probing. If the
 | |
| `QUERY_PROBE` commands in the [initial tests section](#initial-tests)
 | |
| always produce the expected results, but the toolhead does not always
 | |
| stop during G28/PROBE commands, then it is indicative of this issue. A
 | |
| workaround is to set `probe_with_touch_mode: True` in the config file.
 | |
| 
 | |
| The BL-Touch v3.1 may incorrectly enter an error state after a
 | |
| successful probe attempt. The symptoms are an occasional flashing
 | |
| light on the BL-Touch v3.1 that lasts for a couple of seconds after it
 | |
| successfully contacts the bed. Klipper should clear this error
 | |
| automatically and it is generally harmless. However, one may set
 | |
| `probe_with_touch_mode` in the config file to avoid this issue.
 | |
| 
 | |
| Important! Some "clone" devices and the BL-Touch v2.0 (and earlier)
 | |
| may have reduced accuracy when `probe_with_touch_mode` is set to True.
 | |
| Setting this to True also increases the time it takes to deploy the
 | |
| probe. If configuring this value on a "clone" or older BL-Touch
 | |
| device, be sure to test the probe accuracy before and after setting
 | |
| this value (use the `PROBE_ACCURACY` command to test).
 | |
| 
 | |
| Multi-probing without stowing
 | |
| =============================
 | |
| 
 | |
| By default, Klipper will deploy the probe at the start of each probe
 | |
| attempt and then stow the probe afterwards. This repetitive deploying
 | |
| and stowing of the probe may increase the total time of calibration
 | |
| sequences that involve many probe measurements. Klipper supports
 | |
| leaving the probe deployed between consecutive probes, which can
 | |
| reduce the total time of probing. This mode is enabled by configuring
 | |
| `stow_on_each_sample` to False in the config file.
 | |
| 
 | |
| Important! Setting `stow_on_each_sample` to False can lead to Klipper
 | |
| making horizontal toolhead movements while the probe is deployed. Be
 | |
| sure to verify all probing operations have sufficient Z clearance
 | |
| prior to setting this value to False. If there is insufficient
 | |
| clearance then a horizontal move may cause the pin to catch on an
 | |
| obstruction and result in damage to the printer.
 | |
| 
 | |
| Important! It is recommended to use `probe_with_touch_mode` configured
 | |
| to True when using `stow_on_each_sample` configured to False. Some
 | |
| "clone" devices may not detect a subsequent bed contact if
 | |
| `probe_with_touch_mode` is not set. On all devices, using the
 | |
| combination of these two settings simplifies the device signaling,
 | |
| which can improve overall stability.
 | |
| 
 | |
| Note, however, that some "clone" devices and the BL-Touch v2.0 (and
 | |
| earlier) may have reduced accuracy when `probe_with_touch_mode` is set
 | |
| to True. On these devices it is a good idea to test the probe accuracy
 | |
| before and after setting `probe_with_touch_mode` (use the
 | |
| `PROBE_ACCURACY` command to test).
 | |
| 
 | |
| Calibrating the BL-Touch offsets
 | |
| ================================
 | |
| 
 | |
| Follow the directions in the [Probe Calibrate](Probe_Calibrate.md)
 | |
| guide to set the x_offset, y_offset, and z_offset config parameters.
 | |
| 
 | |
| It's a good idea to verify that the Z offset is close to 1mm. If not,
 | |
| then you probably want to move the probe up or down to fix this. You
 | |
| want it to trigger well before the nozzle hits the bed, so that
 | |
| possible stuck filament or a warped bed doesn't affect any probing
 | |
| action. But at the same time, you want the retracted position to be as
 | |
| far above the nozzle as possible to avoid it touching printed parts.
 | |
| If an adjustment is made to the probe position, then rerun the probe
 | |
| calibration steps.
 | |
| 
 | |
| BL-Touch output mode
 | |
| ====================
 | |
| 
 | |
| * A BL-Touch V3.0 supports setting a 5V or OPEN-DRAIN output mode,
 | |
|   a BL-Touch V3.1 supports this too, but can also store this in its
 | |
|   internal EEPROM. If your controller board needs the fixed 5V high
 | |
|   logic level of the 5V mode you may set the 'set_output_mode'
 | |
|   parameter in the [bltouch] section of the printer config file to
 | |
|   "5V".
 | |
| 
 | |
|   *** Only use the 5V mode if your controller boards input line is
 | |
|   5V tolerant. This is why the default configuration of these BL-Touch
 | |
|   versions is OPEN-DRAIN mode. You could potentially damage your
 | |
|   controller boards CPU ***
 | |
| 
 | |
|   So therefore:
 | |
|   If a controller board NEEDs 5V mode AND it is 5V tolerant on its
 | |
|   input signal line AND if
 | |
| 
 | |
|   - you have a BL-Touch Smart V3.0, you need the use 'set_output_mode: 5V'
 | |
|     parameter to ensure this setting at each startup, since the probe
 | |
|     cannot remember the needed setting.
 | |
|   - you have a BL-Touch Smart V3.1, you have the choice of using
 | |
|     'set_output_mode: 5V' or storing the mode once by use of a
 | |
|     'BLTOUCH_STORE MODE=5V' command manually and NOT using the parameter
 | |
|     'set_output_mode:'.
 | |
|   - you have some other probe: Some probes have a trace on the circuit board
 | |
|     to cut or a jumper to set in order to (permanently) set the output mode.
 | |
|     In that case, omit the 'set_output_mode' parameter completely.
 | |
| 
 | |
|   If you have a V3.1, do not automate or repeat storing the output mode to
 | |
|   avoid wearing out the EEPROM of the probe.The BLTouch EEPROM is good for
 | |
|   about 100.000 updates. 100 stores per day would add up to about 3 years
 | |
|   of operation prior to wearing it out. Thus, storing the output mode in a
 | |
|   V3.1 is designed by the vendor to be a complicated operation (the factory
 | |
|   default being a safe OPEN DRAIN mode) and is not suited to be repeatedly
 | |
|   issued by any slicer, macro or anything else, it is preferably only to be
 | |
|   used when first integrating the probe into a printers electronics.
 |