| # Manual leveling
 | |
| 
 | |
| This document describes tools for calibrating a Z endstop and for
 | |
| performing adjustments to bed leveling screws.
 | |
| 
 | |
| ## Calibrating a Z endstop
 | |
| 
 | |
| An accurate Z endstop position is critical to obtaining high quality
 | |
| prints.
 | |
| 
 | |
| Note, though, the accuracy of the Z endstop switch itself can be a
 | |
| limiting factor. If one is using Trinamic stepper motor drivers then
 | |
| consider enabling [endstop phase](Endstop_Phase.md) detection to
 | |
| improve the accuracy of the switch.
 | |
| 
 | |
| To perform a Z endstop calibration, home the printer, command the head
 | |
| to move to a Z position that is at least five millimeters above the
 | |
| bed (if it is not already), command the head to move to an XY position
 | |
| near the center of the bed, then navigate to the OctoPrint terminal
 | |
| tab and run:
 | |
| ```
 | |
| Z_ENDSTOP_CALIBRATE
 | |
| ```
 | |
| Then follow the steps described at
 | |
| ["the paper test"](Bed_Level.md#the-paper-test) to determine the
 | |
| actual distance between the nozzle and bed at the given location. Once
 | |
| those steps are complete one can `ACCEPT` the position and save the
 | |
| results to the config file with:
 | |
| ```
 | |
| SAVE_CONFIG
 | |
| ```
 | |
| 
 | |
| It's preferable to use a Z endstop switch on the opposite end of the Z
 | |
| axis from the bed. (Homing away from the bed is more robust as then it
 | |
| is generally always safe to home the Z.) However, if one must home
 | |
| towards the bed it is recommended to adjust the endstop so that it
 | |
| triggers a small distance (eg, .5mm) above the bed. Almost all endstop
 | |
| switches can safely be depressed a small distance beyond their trigger
 | |
| point. When this is done, one should find that the
 | |
| `Z_ENDSTOP_CALIBRATE` command reports a small positive value (eg,
 | |
| .5mm) for the Z position_endstop. Triggering the endstop while it is
 | |
| still some distance from the bed reduces the risk of inadvertent bed
 | |
| crashes.
 | |
| 
 | |
| Some printers have the ability to manually adjust the location of the
 | |
| physical endstop switch. However, it's recommended to perform Z
 | |
| endstop positioning in software with Klipper - once the physical
 | |
| location of the endstop is in a convenient location, one can make any
 | |
| further adjustments by running Z_ENDSTOP_CALIBRATE or by manually
 | |
| updating the Z position_endstop in the configuration file.
 | |
| 
 | |
| ## Adjusting bed leveling screws
 | |
| 
 | |
| The secret to getting good bed leveling with bed leveling screws is to
 | |
| utilize the printer's high precision motion system during the bed
 | |
| leveling process itself. This is done by commanding the nozzle to a
 | |
| position near each bed screw and then adjusting that screw until the
 | |
| bed is a set distance from the nozzle. Klipper has a tool to assist
 | |
| with this. In order to use the tool it is necessary to specify each
 | |
| screw XY location.
 | |
| 
 | |
| This is done by creating a `[bed_screws]` config section. For example,
 | |
| it might look something similar to:
 | |
| ```
 | |
| [bed_screws]
 | |
| screw1: 100, 50
 | |
| screw2: 100, 150
 | |
| screw3: 150, 100
 | |
| ```
 | |
| 
 | |
| If a bed screw is under the bed, then specify the XY position directly
 | |
| above the screw. If the screw is outside the bed then specify an XY
 | |
| position closest to the screw that is still within the range of the
 | |
| bed.
 | |
| 
 | |
| Once the config file is ready, run `RESTART` to load that config, and
 | |
| then one can start the tool by running:
 | |
| ```
 | |
| BED_SCREWS_ADJUST
 | |
| ```
 | |
| 
 | |
| This tool will move the printer's nozzle to each screw XY location
 | |
| and then move the nozzle to a Z=0 height. At this point one can use the
 | |
| "paper test" to adjust the bed screw directly under the nozzle. See
 | |
| the information described in
 | |
| ["the paper test"](Bed_Level.md#the-paper-test), but adjust the bed
 | |
| screw instead of commanding the nozzle to different heights. Adjust
 | |
| the bed screw until there is a small amount of friction when pushing
 | |
| the paper back and forth.
 | |
| 
 | |
| Once the screw is adjusted so that a small amount of friction is felt,
 | |
| run either the `ACCEPT` or `ADJUSTED` command. Use the `ADJUSTED`
 | |
| command if the bed screw needed an adjustment (typically anything more
 | |
| than about 1/8th of a turn of the screw). Use the `ACCEPT` command if
 | |
| no significant adjustment is necessary. Both commands will cause the
 | |
| tool to proceed to the next screw. (When an `ADJUSTED` command is
 | |
| used, the tool will schedule an additional cycle of bed screw
 | |
| adjustments; the tool completes successfully when all bed screws are
 | |
| verified to not require any significant adjustments.) One can use the
 | |
| `ABORT` command to exit the tool early.
 | |
| 
 | |
| This system works best when the printer has a flat printing surface
 | |
| (such as glass) and has straight rails. Upon successful completion of
 | |
| the bed leveling tool the bed should be ready for printing.
 | |
| 
 | |
| ### Fine grained bed screw adjustments
 | |
| 
 | |
| If the printer uses three bed screws and all three screws are under
 | |
| the bed, then it may be possible to perform a second "high precision"
 | |
| bed leveling step. This is done by commanding the nozzle to locations
 | |
| where the bed moves a larger distance with each bed screw adjustment.
 | |
| 
 | |
| For example, consider a bed with screws at locations A, B, and C:
 | |
| 
 | |
| 
 | |
| 
 | |
| For each adjustment made to the bed screw at location C, the bed will
 | |
| swing along a pendulum defined by the remaining two bed screws (shown
 | |
| here as a green line). In this situation, each adjustment to the bed
 | |
| screw at C will move the bed at position D a further amount than
 | |
| directly at C. It is thus possible to make an improved C screw
 | |
| adjustment when the nozzle is at position D.
 | |
| 
 | |
| To enable this feature, one would determine the additional nozzle
 | |
| coordinates and add them to the config file. For example, it might
 | |
| look like:
 | |
| ```
 | |
| [bed_screws]
 | |
| screw1: 100, 50
 | |
| screw1_fine_adjust: 0, 0
 | |
| screw2: 100, 150
 | |
| screw2_fine_adjust: 300, 300
 | |
| screw3: 150, 100
 | |
| screw3_fine_adjust: 0, 100
 | |
| ```
 | |
| 
 | |
| When this feature is enabled, the `BED_SCREWS_ADJUST` tool will first
 | |
| prompt for coarse adjustments directly above each screw position, and
 | |
| once those are accepted, it will prompt for fine adjustments at the
 | |
| additional locations. Continue to use `ACCEPT` and `ADJUSTED` at each
 | |
| position.
 | |
| 
 | |
| ## Adjusting bed leveling screws using the bed probe
 | |
| 
 | |
| This is another way to calibrate the bed level using the bed probe. To
 | |
| use it you must have a Z probe (BL Touch, Inductive sensor, etc).
 | |
| 
 | |
| To enable this feature, one would determine the nozzle coordinates
 | |
| such that the Z probe is above the screws, and then add them to the
 | |
| config file. For example, it might look like:
 | |
| 
 | |
| ```
 | |
| [screws_tilt_adjust]
 | |
| screw1: -5, 30
 | |
| screw1_name: front left screw
 | |
| screw2: 155, 30
 | |
| screw2_name: front right screw
 | |
| screw3: 155, 190
 | |
| screw3_name: rear right screw
 | |
| screw4: -5, 190
 | |
| screw4_name: rear left screw
 | |
| horizontal_move_z: 10.
 | |
| speed: 50.
 | |
| screw_thread: CW-M3
 | |
| ```
 | |
| 
 | |
| The screw1 is always the reference point for the others, so the system
 | |
| assumes that screw1 is at the correct height. Always run `G28` first
 | |
| and then run `SCREWS_TILT_CALCULATE` - it should produce output
 | |
| similar to:
 | |
| ```
 | |
| Send: G28
 | |
| Recv: ok
 | |
| Send: SCREWS_TILT_CALCULATE
 | |
| Recv: // 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
 | |
| Recv: // front left screw (base) : x=-5.0, y=30.0, z=2.48750
 | |
| Recv: // front right screw : x=155.0, y=30.0, z=2.36000 : adjust CW 01:15
 | |
| Recv: // rear right screw : y=155.0, y=190.0, z=2.71500 : adjust CCW 00:50
 | |
| Recv: // read left screw : x=-5.0, y=190.0, z=2.47250 : adjust CW 00:02
 | |
| Recv: ok
 | |
| ```
 | |
| 
 | |
| This means that:
 | |
| - front left screw is the reference point you must not change it.
 | |
| - front right screw must be turned clockwise 1 full turn and a quarter turn
 | |
| - rear right screw must be turned counter-clockwise 50 minutes
 | |
| - rear left screw must be turned clockwise 2 minutes (not need it's ok)
 | |
| 
 | |
| Note that "minutes" refers to "minutes of a clock face". So, for
 | |
| example, 15 minutes is a quarter of a full turn.
 | |
| 
 | |
| Repeat the process several times until you get a good level bed -
 | |
| normally when all adjustments are below 6 minutes.
 | |
| 
 | |
| If using a probe that is mounted on the side of the hotend (that is,
 | |
| it has an X or Y offset) then note that adjusting the bed tilt will
 | |
| invalidate any previous probe calibration that was performed with a
 | |
| tilted bed. Be sure to run [probe calibration](Probe_Calibrate.md)
 | |
| after the bed screws have been adjusted.
 | |
| 
 | |
| The `MAX_DEVIATION` parameter is useful when a saved bed mesh is used,
 | |
| to ensure that the bed level has not drifted too far from where it was when
 | |
| the mesh was created. For example, `SCREWS_TILT_CALCULATE MAX_DEVIATION=0.01`
 | |
| can be added to the custom start gcode of the slicer before the mesh is loaded.
 | |
| It will abort the print if the configured limit is exceeded (0.01mm in this
 | |
| example), giving the user a chance to adjust the screws and restart the print.
 | |
| 
 | |
| The `DIRECTION` parameter is useful if you can turn your bed adjustment
 | |
| screws in one direction only. For example, you might have screws that start
 | |
| tightened in their lowest (or highest) possible position, which can only be
 | |
| turned in a single direction, to raise (or lower) the bed. If you can only
 | |
| turn the screws clockwise, run `SCREWS_TILT_CALCULATE DIRECTION=CW`. If you can
 | |
| only turn them counter-clockwise, run `SCREWS_TILT_CALCULATE DIRECTION=CCW`.
 | |
| A suitable reference point will be chosen such that the bed can be leveled
 | |
| by turning all the screws in the given direction.
 |