	HTU21D sensor class lacked the method `get_report_time_delta` invoked during watermark control loops. This short fix simply adds that method in, calling the `self.report_time` attribute created during class construction. Signed-off-by: Jon Sanders <jonsan@gmail.com>
		
			
				
	
	
		
			249 lines
		
	
	
		
			9.0 KiB
		
	
	
	
		
			Python
		
	
	
	
	
	
			
		
		
	
	
			249 lines
		
	
	
		
			9.0 KiB
		
	
	
	
		
			Python
		
	
	
	
	
	
# HTU21D(F)/Si7013/Si7020/Si7021/SHT21 i2c based temperature sensors support
 | 
						|
#
 | 
						|
# Copyright (C) 2020  Lucio Tarantino <lucio.tarantino@gmail.com>
 | 
						|
#
 | 
						|
# This file may be distributed under the terms of the GNU GPLv3 license.
 | 
						|
import logging
 | 
						|
from . import bus
 | 
						|
 | 
						|
######################################################################
 | 
						|
# NOTE: The implementation requires write support of length 0
 | 
						|
#       before reading on the i2c bus of the mcu.
 | 
						|
#
 | 
						|
# Compatible Sensors:
 | 
						|
#       HTU21D - Tested on Linux MCU.
 | 
						|
#       Si7013 - Untested
 | 
						|
#       Si7020 - Untested
 | 
						|
#       Si7021 - Untested
 | 
						|
#       SHT21  - Untested
 | 
						|
#
 | 
						|
######################################################################
 | 
						|
 | 
						|
HTU21D_I2C_ADDR= 0x40
 | 
						|
 | 
						|
HTU21D_COMMANDS = {
 | 
						|
    'HTU21D_TEMP'       :0xE3,
 | 
						|
    'HTU21D_HUMID'      :0xE5,
 | 
						|
    'HTU21D_TEMP_NH'    :0xF3,
 | 
						|
    'HTU21D_HUMID_NH'   :0xF5,
 | 
						|
    'WRITE'             :0xE6,
 | 
						|
    'READ'              :0xE7,
 | 
						|
    'RESET'             :0xFE,
 | 
						|
    'SERIAL'            :[0xFA,0x0F,0xFC,0xC9],
 | 
						|
    'FIRMWARE_READ'     :[0x84,0xB8]
 | 
						|
 | 
						|
}
 | 
						|
 | 
						|
HTU21D_RESOLUTION_MASK = 0x7E;
 | 
						|
HTU21D_RESOLUTIONS = {
 | 
						|
    'TEMP14_HUM12':int('00000000',2),
 | 
						|
    'TEMP13_HUM10':int('10000000',2),
 | 
						|
    'TEMP12_HUM08':int('00000001',2),
 | 
						|
    'TEMP11_HUM11':int('10000001',2)
 | 
						|
}
 | 
						|
 | 
						|
# Device with conversion time for tmp/resolution bit
 | 
						|
# The format is:
 | 
						|
#  <CHIPNAME>:{id:<ID>, ..<RESOlUTION>:[<temp time>,<humidity time>].. }
 | 
						|
HTU21D_DEVICES = {
 | 
						|
    'SI7013':{'id':0x0D,
 | 
						|
        'TEMP14_HUM12':[.11,.12],
 | 
						|
        'TEMP13_HUM10':[ .7, .5],
 | 
						|
        'TEMP12_HUM08':[ .4, .4],
 | 
						|
        'TEMP11_HUM11':[ .3, .7]},
 | 
						|
    'SI7020':{'id':0x14,
 | 
						|
        'TEMP14_HUM12':[.11,.12],
 | 
						|
        'TEMP13_HUM10':[ .7, .5],
 | 
						|
        'TEMP12_HUM08':[ .4, .4],
 | 
						|
        'TEMP11_HUM11':[ .3, .7]},
 | 
						|
    'SI7021':{'id':0x14,
 | 
						|
        'TEMP14_HUM12':[.11,.12],
 | 
						|
        'TEMP13_HUM10':[ .7, .5],
 | 
						|
        'TEMP12_HUM08':[ .4, .4],
 | 
						|
        'TEMP11_HUM11':[ .3, .7]},
 | 
						|
    'SHT21': {'id':0x31,
 | 
						|
        'TEMP14_HUM12':[.85,.29],
 | 
						|
        'TEMP13_HUM10':[.43, .9],
 | 
						|
        'TEMP12_HUM08':[.22, .4],
 | 
						|
        'TEMP11_HUM11':[.11,.15]},
 | 
						|
    'HTU21D':{'id':0x32,
 | 
						|
        'TEMP14_HUM12':[.50,.16],
 | 
						|
        'TEMP13_HUM10':[.25, .5],
 | 
						|
        'TEMP12_HUM08':[.13, .3],
 | 
						|
        'TEMP11_HUM11':[.12, .8]}
 | 
						|
}
 | 
						|
#temperature coefficient for RH compensation at range 0C..80C,
 | 
						|
#  for HTU21D & SHT21 only
 | 
						|
HTU21D_TEMP_COEFFICIENT= -0.15
 | 
						|
#crc8 polynomial for 16bit value, CRC8 -> x^8 + x^5 + x^4 + 1
 | 
						|
HTU21D_CRC8_POLYNOMINAL= 0x13100
 | 
						|
 | 
						|
class HTU21D:
 | 
						|
    def __init__(self, config):
 | 
						|
        self.printer = config.get_printer()
 | 
						|
        self.name = config.get_name().split()[-1]
 | 
						|
        self.reactor = self.printer.get_reactor()
 | 
						|
        self.i2c = bus.MCU_I2C_from_config(
 | 
						|
            config, default_addr=HTU21D_I2C_ADDR, default_speed=100000)
 | 
						|
        self.hold_master_mode = config.getboolean('htu21d_hold_master',False)
 | 
						|
        self.resolution = config.get('htu21d_resolution','TEMP12_HUM08')
 | 
						|
        self.report_time = config.getint('htu21d_report_time',30,minval=5)
 | 
						|
        if self.resolution not in HTU21D_RESOLUTIONS:
 | 
						|
            raise config.error("Invalid HTU21D Resolution. Valid are %s"
 | 
						|
                % '|'.join(HTU21D_RESOLUTIONS.keys()))
 | 
						|
        self.deviceId = config.get('sensor_type')
 | 
						|
        self.temp = self.min_temp = self.max_temp = self.humidity = 0.
 | 
						|
        self.sample_timer = self.reactor.register_timer(self._sample_htu21d)
 | 
						|
        self.printer.add_object("htu21d " + self.name, self)
 | 
						|
        self.printer.register_event_handler("klippy:connect",
 | 
						|
                                            self.handle_connect)
 | 
						|
 | 
						|
    def handle_connect(self):
 | 
						|
        self._init_htu21d()
 | 
						|
        self.reactor.update_timer(self.sample_timer, self.reactor.NOW)
 | 
						|
 | 
						|
    def setup_minmax(self, min_temp, max_temp):
 | 
						|
        self.min_temp = min_temp
 | 
						|
        self.max_temp = max_temp
 | 
						|
 | 
						|
    def setup_callback(self, cb):
 | 
						|
        self._callback = cb
 | 
						|
 | 
						|
    def get_report_time_delta(self):
 | 
						|
        return self.report_time
 | 
						|
 | 
						|
    def _init_htu21d(self):
 | 
						|
        # Device Soft Reset
 | 
						|
        self.i2c.i2c_write([HTU21D_COMMANDS['RESET']])
 | 
						|
        # Wait 15ms after reset
 | 
						|
        self.reactor.pause(self.reactor.monotonic() + .15)
 | 
						|
 | 
						|
        # Read ChipId
 | 
						|
        params = self.i2c.i2c_read([HTU21D_COMMANDS['SERIAL'][2],
 | 
						|
                                    HTU21D_COMMANDS['SERIAL'][3]], 3)
 | 
						|
        response = bytearray(params['response'])
 | 
						|
        rdevId = response[0] << 8
 | 
						|
        rdevId |= response[1]
 | 
						|
        checksum = response[2]
 | 
						|
        if self._chekCRC8(rdevId) != checksum:
 | 
						|
            logging.warn("htu21d: Reading deviceId !Checksum error!")
 | 
						|
        rdevId = rdevId >> 8
 | 
						|
        deviceId_list = list(
 | 
						|
            filter(
 | 
						|
              lambda elem: HTU21D_DEVICES[elem]['id'] == rdevId,HTU21D_DEVICES)
 | 
						|
            )
 | 
						|
        if len(deviceId_list) != 0:
 | 
						|
            logging.info("htu21d: Found Device Type %s" % deviceId_list[0])
 | 
						|
        else:
 | 
						|
            logging.warn("htu21d: Unknown Device ID %#x " % rdevId)
 | 
						|
 | 
						|
        if(self.deviceId != deviceId_list[0]):
 | 
						|
            logging.warn(
 | 
						|
                "htu21d: Found device %s. Forcing to type %s as config.",
 | 
						|
                 deviceId_list[0],self.deviceId)
 | 
						|
 | 
						|
        # Set Resolution
 | 
						|
        params = self.i2c.i2c_read([HTU21D_COMMANDS['READ']], 1)
 | 
						|
        response = bytearray(params['response'])
 | 
						|
        registerData = response[0] & HTU21D_RESOLUTION_MASK
 | 
						|
        registerData |= HTU21D_RESOLUTIONS[self.resolution]
 | 
						|
        self.i2c.i2c_write([HTU21D_COMMANDS['WRITE']],registerData)
 | 
						|
        logging.info("htu21d: Setting resolution to %s " % self.resolution)
 | 
						|
 | 
						|
    def _sample_htu21d(self, eventtime):
 | 
						|
        try:
 | 
						|
            # Read Temeprature
 | 
						|
            if self.hold_master_mode:
 | 
						|
                params = self.i2c.i2c_write([HTU21D_COMMANDS['HTU21D_TEMP']])
 | 
						|
            else:
 | 
						|
                params = self.i2c.i2c_write([HTU21D_COMMANDS['HTU21D_TEMP_NH']])
 | 
						|
 | 
						|
            # Wait
 | 
						|
            self.reactor.pause(self.reactor.monotonic()
 | 
						|
            + HTU21D_DEVICES[self.deviceId][self.resolution][0])
 | 
						|
 | 
						|
 | 
						|
            params = self.i2c.i2c_read([],3)
 | 
						|
 | 
						|
            response = bytearray(params['response'])
 | 
						|
            rtemp  = response[0] << 8
 | 
						|
            rtemp |= response[1]
 | 
						|
            if self._chekCRC8(rtemp) != response[2]:
 | 
						|
                logging.warn("htu21d: Checksum error on Temperature reading!")
 | 
						|
            else:
 | 
						|
                self.temp = (0.002681 * float(rtemp) - 46.85)
 | 
						|
                logging.debug("htu21d: Temperature %.2f " % self.temp)
 | 
						|
 | 
						|
            # Read Humidity
 | 
						|
            if self.hold_master_mode:
 | 
						|
                self.i2c.i2c_write([HTU21D_COMMANDS['HTU21D_HUMID']])
 | 
						|
            else:
 | 
						|
                self.i2c.i2c_write([HTU21D_COMMANDS['HTU21D_HUMID_NH']])
 | 
						|
 | 
						|
            # Wait
 | 
						|
            self.reactor.pause(self.reactor.monotonic()
 | 
						|
            + HTU21D_DEVICES[self.deviceId][self.resolution][1])
 | 
						|
 | 
						|
            params = self.i2c.i2c_read([],3)
 | 
						|
 | 
						|
            response = bytearray(params['response'])
 | 
						|
            rhumid = response[0] << 8
 | 
						|
            rhumid|= response[1]
 | 
						|
            if self._chekCRC8(rhumid) != response[2]:
 | 
						|
                logging.warn("htu21d: Checksum error on Humidity reading!")
 | 
						|
            else:
 | 
						|
                #clear status bits,
 | 
						|
                # humidity always returns xxxxxx10 in the LSB field
 | 
						|
                rhumid   ^= 0x02;
 | 
						|
                self.humidity = (0.001907 * float(rhumid) - 6)
 | 
						|
                if (self.humidity < 0):
 | 
						|
                    #due to RH accuracy, measured value might be
 | 
						|
                    # slightly less than 0 or more 100
 | 
						|
                    self.temp = 0
 | 
						|
                elif (self.humidity > 100):
 | 
						|
                    self.humidity = 100
 | 
						|
                # Only for HTU21D & SHT21.
 | 
						|
                # Calculates temperature compensated Humidity, %RH
 | 
						|
                if( self.deviceId in ['SHT21','HTU21D']
 | 
						|
                    and self.temp > 0 and self.temp < 80):
 | 
						|
                    logging.debug("htu21d: Do temp compensation..")
 | 
						|
                    self.humidity = self.humidity
 | 
						|
                    + (25.0 - self.temp) * HTU21D_TEMP_COEFFICIENT;
 | 
						|
                logging.debug("htu21d: Humidity %.2f " % self.humidity)
 | 
						|
        except Exception:
 | 
						|
            logging.exception("htu21d: Error reading data")
 | 
						|
            self.temp = self.humidity = .0
 | 
						|
            return self.reactor.NEVER
 | 
						|
 | 
						|
        if self.temp < self.min_temp or self.temp > self.max_temp:
 | 
						|
            self.printer.invoke_shutdown(
 | 
						|
                "HTU21D temperature %0.1f outside range of %0.1f:%.01f"
 | 
						|
                % (self.temp, self.min_temp, self.max_temp))
 | 
						|
 | 
						|
        measured_time = self.reactor.monotonic()
 | 
						|
        print_time = self.i2c.get_mcu().estimated_print_time(measured_time)
 | 
						|
        self._callback(print_time, self.temp)
 | 
						|
        return measured_time + self.report_time
 | 
						|
 | 
						|
    def _chekCRC8(self,data):
 | 
						|
        for bit in range(0,16):
 | 
						|
            if (data & 0x8000):
 | 
						|
                data = (data << 1) ^ HTU21D_CRC8_POLYNOMINAL;
 | 
						|
            else:
 | 
						|
                data <<= 1
 | 
						|
        data = data >> 8
 | 
						|
        return data
 | 
						|
 | 
						|
    def get_status(self, eventtime):
 | 
						|
        return {
 | 
						|
            'temperature': self.temp,
 | 
						|
            'humidity': self.humidity,
 | 
						|
        }
 | 
						|
 | 
						|
 | 
						|
def load_config(config):
 | 
						|
    # Register sensor
 | 
						|
    pheater = config.get_printer().lookup_object("heaters")
 | 
						|
    for stype in HTU21D_DEVICES:
 | 
						|
        pheater.add_sensor_factory(stype, HTU21D)
 |