@@ -5611,17 +5611,22 @@ the <a href="G-Codes.html#input_shaper">command reference</a>.</p>
|
||||
# input shapers, this parameter can be set from different
|
||||
# considerations. The default value is 0, which disables input
|
||||
# shaping for Y axis.
|
||||
#shaper_freq_z: 0
|
||||
# A frequency (in Hz) of the input shaper for Z axis. The default
|
||||
# value is 0, which disables input shaping for Z axis.
|
||||
#shaper_type: mzv
|
||||
# A type of the input shaper to use for both X and Y axes. Supported
|
||||
# A type of the input shaper to use for all axes. Supported
|
||||
# shapers are zv, mzv, zvd, ei, 2hump_ei, and 3hump_ei. The default
|
||||
# is mzv input shaper.
|
||||
#shaper_type_x:
|
||||
#shaper_type_y:
|
||||
# If shaper_type is not set, these two parameters can be used to
|
||||
# configure different input shapers for X and Y axes. The same
|
||||
#shaper_type_z:
|
||||
# If shaper_type is not set, these parameters can be used to
|
||||
# configure different input shapers for X, Y, and Z axes. The same
|
||||
# values are supported as for shaper_type parameter.
|
||||
#damping_ratio_x: 0.1
|
||||
#damping_ratio_y: 0.1
|
||||
#damping_ratio_z: 0.1
|
||||
# Damping ratios of vibrations of X and Y axes used by input shapers
|
||||
# to improve vibration suppression. Default value is 0.1 which is a
|
||||
# good all-round value for most printers. In most circumstances this
|
||||
@@ -5780,6 +5785,10 @@ section of the measuring resonances guide for more information on
|
||||
# and on the toolhead (for X axis). These parameters have the same
|
||||
# format as 'accel_chip' parameter. Only 'accel_chip' or these two
|
||||
# parameters must be provided.
|
||||
#accel_chip_z:
|
||||
# A name of the accelerometer chip to use for measurements of Z axis.
|
||||
# This parameter has the same format as 'accel_chip'. The default is
|
||||
# not to configure an accelerometer for Z axis.
|
||||
#max_smoothing:
|
||||
# Maximum input shaper smoothing to allow for each axis during shaper
|
||||
# auto-calibration (with 'SHAPER_CALIBRATE' command). By default no
|
||||
@@ -5792,6 +5801,8 @@ section of the measuring resonances guide for more information on
|
||||
# Minimum frequency to test for resonances. The default is 5 Hz.
|
||||
#max_freq: 135
|
||||
# Maximum frequency to test for resonances. The default is 135 Hz.
|
||||
#max_freq_z: 100
|
||||
# Maximum frequency to test Z axis for resonances. The default is 100 Hz.
|
||||
#accel_per_hz: 60
|
||||
# This parameter is used to determine which acceleration to use to
|
||||
# test a specific frequency: accel = accel_per_hz * freq. Higher the
|
||||
@@ -5799,6 +5810,9 @@ section of the measuring resonances guide for more information on
|
||||
# a lower than the default value if the resonances get too strong on
|
||||
# the printer. However, lower values make measurements of high-frequency
|
||||
# resonances less precise. The default value is 60 (mm/sec).
|
||||
#accel_per_hz_z: 15
|
||||
# This parameter has the same meaning as accel_per_hz, but applies to
|
||||
# Z axis specifically. The default is 15 (mm/sec).
|
||||
#hz_per_sec: 1
|
||||
# Determines the speed of the test. When testing all frequencies in
|
||||
# range [min_freq, max_freq], each second the frequency increases by
|
||||
@@ -5807,6 +5821,8 @@ section of the measuring resonances guide for more information on
|
||||
# (Hz/sec == sec^-2).
|
||||
#sweeping_accel: 400
|
||||
# An acceleration of slow sweeping moves. The default is 400 mm/sec^2.
|
||||
#sweeping_accel_z: 50
|
||||
# Same as sweeping_accel above, but for Z axis. The default is 50 mm/sec^2.
|
||||
#sweeping_period: 1.2
|
||||
# A period of slow sweeping moves. Setting this parameter to 0
|
||||
# disables slow sweeping moves. Avoid setting it to a too small
|
||||
|
||||
29
G-Codes.html
29
G-Codes.html
@@ -5614,15 +5614,17 @@ been enabled (also see the
|
||||
<a href="Resonance_Compensation.html">resonance compensation guide</a>).</p>
|
||||
<h4 id="set_input_shaper">SET_INPUT_SHAPER<a class="headerlink" href="#set_input_shaper" title="Permanent link">¶</a></h4>
|
||||
<p><code>SET_INPUT_SHAPER [SHAPER_FREQ_X=<shaper_freq_x>]
|
||||
[SHAPER_FREQ_Y=<shaper_freq_y>] [DAMPING_RATIO_X=<damping_ratio_x>]
|
||||
[DAMPING_RATIO_Y=<damping_ratio_y>] [SHAPER_TYPE=<shaper>]
|
||||
[SHAPER_TYPE_X=<shaper_type_x>] [SHAPER_TYPE_Y=<shaper_type_y>]</code>:
|
||||
[SHAPER_FREQ_Y=<shaper_freq_y>] [SHAPER_FREQ_Y=<shaper_freq_z>]
|
||||
[DAMPING_RATIO_X=<damping_ratio_x>] [DAMPING_RATIO_Y=<damping_ratio_y>]
|
||||
[DAMPING_RATIO_Z=<damping_ratio_z>] [SHAPER_TYPE=<shaper>]
|
||||
[SHAPER_TYPE_X=<shaper_type_x>] [SHAPER_TYPE_Y=<shaper_type_y>]
|
||||
[SHAPER_TYPE_Z=<shaper_type_z>]</code>:
|
||||
Modify input shaper parameters. Note that SHAPER_TYPE parameter resets
|
||||
input shaper for both X and Y axes even if different shaper types have
|
||||
input shaper for all axes even if different shaper types have
|
||||
been configured in [input_shaper] section. SHAPER_TYPE cannot be used
|
||||
together with either of SHAPER_TYPE_X and SHAPER_TYPE_Y parameters.
|
||||
See <a href="Config_Reference.html#input_shaper">config reference</a> for more
|
||||
details on each of these parameters.</p>
|
||||
together with any of SHAPER_TYPE_X, SHAPER_TYPE_Y, and SHAPER_TYPE_Z
|
||||
parameters. See <a href="Config_Reference.html#input_shaper">config reference</a>
|
||||
for more details on each of these parameters.</p>
|
||||
<h3 id="led">[led]<a class="headerlink" href="#led" title="Permanent link">¶</a></h3>
|
||||
<p>The following command is available when any of the
|
||||
<a href="Config_Reference.html#leds">led config sections</a> are enabled.</p>
|
||||
@@ -6002,13 +6004,14 @@ all enabled accelerometer chips.</p>
|
||||
[POINT=x,y,z] [INPUT_SHAPING=<0:1>]</code>: Runs the resonance
|
||||
test in all configured probe points for the requested "axis" and
|
||||
measures the acceleration using the accelerometer chips configured for
|
||||
the respective axis. "axis" can either be X or Y, or specify an
|
||||
arbitrary direction as <code>AXIS=dx,dy</code>, where dx and dy are floating
|
||||
the respective axis. "axis" can either be X, Y or Z, or specify an
|
||||
arbitrary direction as <code>AXIS=dx,dy[,dz]</code>, where dx, dy, dz are floating
|
||||
point numbers defining a direction vector (e.g. <code>AXIS=X</code>, <code>AXIS=Y</code>, or
|
||||
<code>AXIS=1,-1</code> to define a diagonal direction). Note that <code>AXIS=dx,dy</code>
|
||||
and <code>AXIS=-dx,-dy</code> is equivalent. <code>chip_name</code> can be one or
|
||||
more configured accel chips, delimited with comma, for example
|
||||
<code>CHIPS="adxl345, adxl345 rpi"</code>. If POINT is specified it will override the point(s)
|
||||
<code>AXIS=1,-1</code> to define a diagonal direction in XY plane, or <code>AXIS=0,1,1</code>
|
||||
to define a direction in YZ plane). Note that <code>AXIS=dx,dy</code> and <code>AXIS=-dx,-dy</code>
|
||||
is equivalent. <code>chip_name</code> can be one or more configured accel chips,
|
||||
delimited with comma, for example <code>CHIPS="adxl345, adxl345 rpi"</code>.
|
||||
If POINT is specified it will override the point(s)
|
||||
configured in <code>[resonance_tester]</code>. If <code>INPUT_SHAPING=0</code> or not set(default),
|
||||
disables input shaping for the resonance testing, because
|
||||
it is not valid to run the resonance testing with the input shaper
|
||||
|
||||
@@ -990,6 +990,13 @@
|
||||
Selecting max_accel
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#measuring-the-resonances-of-z-axis" class="md-nav__link">
|
||||
Measuring the resonances of Z axis
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
@@ -1873,6 +1880,13 @@
|
||||
Selecting max_accel
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#measuring-the-resonances-of-z-axis" class="md-nav__link">
|
||||
Measuring the resonances of Z axis
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
@@ -2691,6 +2705,86 @@ to specify it explicitly.</p>
|
||||
<p>If you are doing a shaper re-calibration and the reported smoothing for the
|
||||
suggested shaper configuration is almost the same as what you got during the
|
||||
previous calibration, this step can be skipped.</p>
|
||||
<h3 id="measuring-the-resonances-of-z-axis">Measuring the resonances of Z axis<a class="headerlink" href="#measuring-the-resonances-of-z-axis" title="Permanent link">¶</a></h3>
|
||||
<p>Measuring the resonances of Z axis is similar in many aspects to measuring
|
||||
resonances of X and Y axes, with some subtle differences. Similarly to other
|
||||
axes measurements, you will need to have an accelerometer mounted on the
|
||||
moving parts of Z axis - either the bed itself (if the bed moves over Z axis),
|
||||
or the toolhead (if the toolhead/gantry moves over Z). You will need to
|
||||
add the appropriate chip configuration to <code>printer.cfg</code> and also add it to
|
||||
<code>[resonance_tester]</code> section, e.g.</p>
|
||||
<div class="highlight"><pre><span></span><code>[resonance_tester]
|
||||
accel_chip_z: <accelerometer full name>
|
||||
</code></pre></div>
|
||||
|
||||
<p>Also make sure that <code>probe_points</code> configured in <code>[resonance_tester]</code> allow
|
||||
sufficient clearance for Z axis movements (20 mm above bed surface should
|
||||
provide enough clearance with the default test parameters).</p>
|
||||
<p>The next consideration is that Z axis can typically reach lower maximum
|
||||
speeds and accelerations that X and Y axes. Default parameters of the test
|
||||
take that into consideration and are much less agressive, but it may still
|
||||
be necessary to increase <code>max_z_accel</code> and <code>max_z_velocity</code>. If you have
|
||||
them configured in <code>[printer]</code> section, make sure to set them to at least</p>
|
||||
<div class="highlight"><pre><span></span><code>[printer]
|
||||
max_z_velocity: 20
|
||||
max_z_accel: 1550
|
||||
</code></pre></div>
|
||||
|
||||
<p>but only for the duration of the test, afterwards you can revert them back
|
||||
to their original values if necessary. And if you use custom test parameters
|
||||
for Z axis, <code>TEST_RESONANCES</code> and <code>SHAPER_CALIBRATE</code> will provide the minimum
|
||||
required limits if necessary for your specific case.</p>
|
||||
<p>After all changes to <code>printer.cfg</code> have been made, restart Klipper and run
|
||||
either</p>
|
||||
<div class="highlight"><pre><span></span><code>TEST_RESONANCES AXIS=Z
|
||||
</code></pre></div>
|
||||
|
||||
<p>or</p>
|
||||
<div class="highlight"><pre><span></span><code>SHAPER_CALIBRATE AXIS=Z
|
||||
</code></pre></div>
|
||||
|
||||
<p>and proceed from there accordingly how you would for other axes.
|
||||
For example, after <code>TEST_RESONANCES</code> command you can run
|
||||
<code>calibrate_shaper.py</code> script and get shaper recommendations and
|
||||
the chart of resonance response:</p>
|
||||
<p><img alt="Resonances" src="img/calibrate-z.png" /></p>
|
||||
<p>After the calibration, the shaper parameters can be stored in the
|
||||
<code>printer.cfg</code>, e.g. from the example above:</p>
|
||||
<div class="highlight"><pre><span></span><code>[input_shaper]
|
||||
...
|
||||
shaper_type_z: mzv
|
||||
shaper_freq_z: 42.6
|
||||
</code></pre></div>
|
||||
|
||||
<p>Also, given the movements of Z axis are slow, you can easily consider
|
||||
more aggressive input shapers, e.g.</p>
|
||||
<div class="highlight"><pre><span></span><code>[input_shaper]
|
||||
...
|
||||
shaper_type_z: 2hump_ei
|
||||
shaper_freq_z: 63.0
|
||||
</code></pre></div>
|
||||
|
||||
<p>If the test produces bogus results, you may try to increase
|
||||
<code>accel_per_hz_z</code> parameter in <code>[resonance_tester]</code> from its
|
||||
default value 15 to a larger value in the range of 20-30, e.g.</p>
|
||||
<div class="highlight"><pre><span></span><code>[resonance_tester]
|
||||
accel_per_hz_z: 25
|
||||
</code></pre></div>
|
||||
|
||||
<p>and repeat the test. Increasing this value will likely require
|
||||
increasing <code>max_z_accel</code> and <code>max_z_velocity</code> parameters as well.
|
||||
You can run <code>TEST_RESONANCES AXIS=Z</code> command to get the required
|
||||
minimum values.</p>
|
||||
<p>However, if you are unable to measure the resonances of Z axis,
|
||||
you can consider just using</p>
|
||||
<div class="highlight"><pre><span></span><code>[input_shaper]
|
||||
...
|
||||
shaper_type_z: 3hump_ei
|
||||
shaper_freq_z: 65
|
||||
</code></pre></div>
|
||||
|
||||
<p>as an acceptable all-round choice, given that the smoothing of
|
||||
Z axis movements is not of particular concerns.</p>
|
||||
<h3 id="unreliable-measurements-of-resonance-frequencies">Unreliable measurements of resonance frequencies<a class="headerlink" href="#unreliable-measurements-of-resonance-frequencies" title="Permanent link">¶</a></h3>
|
||||
<p>Sometimes the resonance measurements can produce bogus results, leading to
|
||||
the incorrect suggestions for the input shapers. This can be caused by a
|
||||
|
||||
@@ -856,6 +856,13 @@
|
||||
Does input_shaper affect print time?
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#should-i-enable-and-tune-input-shaper-for-z-axis" class="md-nav__link">
|
||||
Should I enable and tune input shaper for Z axis?
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
</ul>
|
||||
@@ -1612,6 +1619,13 @@
|
||||
Does input_shaper affect print time?
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#should-i-enable-and-tune-input-shaper-for-z-axis" class="md-nav__link">
|
||||
Should I enable and tune input shaper for Z axis?
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
</ul>
|
||||
@@ -2034,9 +2048,11 @@ gcode:
|
||||
</code></pre></div>
|
||||
|
||||
<p>Note that <code>SHAPER_TYPE_Y</code> and <code>SHAPER_FREQ_Y</code> should be the same in both
|
||||
commands. It is also possible to put a similar snippet into the start g-code
|
||||
in the slicer, however then the shaper will not be enabled until any print
|
||||
is started.</p>
|
||||
commands. If you need to configure an input shaper for Z axis, include
|
||||
its parameters in both <code>SET_INPUT_SHAPER</code> commands.</p>
|
||||
<p>Besides <code>delayed_gcode</code>, it is also possible to put a similar snippet into
|
||||
the start g-code in the slicer, however then the shaper will not be enabled
|
||||
until any print is started.</p>
|
||||
<p>Note that the input shaper only needs to be configured once. Subsequent changes
|
||||
of the carriages or their modes via <code>SET_DUAL_CARRIAGE</code> command will preserve
|
||||
the configured input shaper parameters.</p>
|
||||
@@ -2044,6 +2060,16 @@ the configured input shaper parameters.</p>
|
||||
<p>No, <code>input_shaper</code> feature has pretty much no impact on the print times by
|
||||
itself. However, the value of <code>max_accel</code> certainly does (tuning of this
|
||||
parameter described in <a href="#selecting-max_accel">this section</a>).</p>
|
||||
<h3 id="should-i-enable-and-tune-input-shaper-for-z-axis">Should I enable and tune input shaper for Z axis?<a class="headerlink" href="#should-i-enable-and-tune-input-shaper-for-z-axis" title="Permanent link">¶</a></h3>
|
||||
<p>Most of the users are not likely to see improvements in the quality of
|
||||
the prints directly, much unlike X and Y shapers. However, users of
|
||||
delta printers, printers with flying gantry, or printers with heavy
|
||||
moving beds may be able to increase the <code>max_z_accel</code> and <code>max_z_velocity</code>
|
||||
kinematics limits and thus get faster Z movements. This can be especially
|
||||
useful e.g. for toolchangers, but also when Z-hops are enabled in slicer.
|
||||
And in general, after enabling Z input shaper many users will hear that
|
||||
Z axis operates more smoothly, which may increase the comfort of printer
|
||||
operation, and may somewhat extend lifespan of Z axis parts.</p>
|
||||
<h2 id="technical-details">Technical details<a class="headerlink" href="#technical-details" title="Permanent link">¶</a></h2>
|
||||
<h3 id="input-shapers">Input shapers<a class="headerlink" href="#input-shapers" title="Permanent link">¶</a></h3>
|
||||
<p>This section contains a brief overview of some technical aspects of the
|
||||
|
||||
Binary file not shown.
Binary file not shown.
BIN
fr/img/calibrate-z.png
Normal file
BIN
fr/img/calibrate-z.png
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 158 KiB |
Binary file not shown.
Binary file not shown.
BIN
hu/img/calibrate-z.png
Normal file
BIN
hu/img/calibrate-z.png
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 158 KiB |
Binary file not shown.
BIN
img/calibrate-z.png
Normal file
BIN
img/calibrate-z.png
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 158 KiB |
Binary file not shown.
BIN
it/img/calibrate-z.png
Normal file
BIN
it/img/calibrate-z.png
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 158 KiB |
Binary file not shown.
File diff suppressed because one or more lines are too long
BIN
sitemap.xml.gz
BIN
sitemap.xml.gz
Binary file not shown.
Binary file not shown.
BIN
zh-Hant/img/calibrate-z.png
Normal file
BIN
zh-Hant/img/calibrate-z.png
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 158 KiB |
Binary file not shown.
Binary file not shown.
BIN
zh/img/calibrate-z.png
Normal file
BIN
zh/img/calibrate-z.png
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 158 KiB |
Binary file not shown.
Reference in New Issue
Block a user