											2018-03-08 14:06:24 -05:00
										 |  |  | This document describes the commands that Klipper supports. These are | 
					
						
							|  |  |  | commands that one may enter into the OctoPrint terminal tab. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | # G-Code commands
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Klipper supports the following standard G-Code commands: | 
					
						
							|  |  |  | - Move (G0 or G1): `G1 [X<pos>] [Y<pos>] [Z<pos>] [E<pos>] [F<speed>]` | 
					
						
							|  |  |  | - Dwell: `G4 P<milliseconds>` | 
					
						
							|  |  |  | - Move to origin: `G28 [X] [Y] [Z]` | 
					
						
							|  |  |  | - Turn off motors: `M18` or `M84` | 
					
						
							|  |  |  | - Wait for current moves to finish: `M400` | 
					
						
							| 
									
										
										
										
											2018-03-08 14:40:26 -05:00
										 |  |  | - Select tool: `T<index>` | 
					
						
							| 
									
										
										
										
											2018-03-08 14:06:24 -05:00
										 |  |  | - Use absolute/relative distances for extrusion: `M82`, `M83` | 
					
						
							|  |  |  | - Use absolute/relative coordinates: `G90`, `G91` | 
					
						
							|  |  |  | - Set position: `G92 [X<pos>] [Y<pos>] [Z<pos>] [E<pos>]` | 
					
						
							| 
									
										
										
										
											2018-03-18 11:29:40 -04:00
										 |  |  | - Set speed factor override percentage: `M220 S<percent>` | 
					
						
							| 
									
										
										
										
											2018-03-08 14:06:24 -05:00
										 |  |  | - Set extrude factor override percentage: `M221 S<percent>` | 
					
						
							|  |  |  | - Get extruder temperature: `M105` | 
					
						
							|  |  |  | - Set extruder temperature: `M104 [T<index>] [S<temperature>]` | 
					
						
							|  |  |  | - Set extruder temperature and wait: `M109 [T<index>] S<temperature>` | 
					
						
							|  |  |  | - Set bed temperature: `M140 [S<temperature>]` | 
					
						
							|  |  |  | - Set bed temperature and wait: `M190 S<temperature>` | 
					
						
							|  |  |  | - Set fan speed: `M106 S<value>` | 
					
						
							|  |  |  | - Turn fan off: `M107` | 
					
						
							|  |  |  | - Emergency stop: `M112` | 
					
						
							|  |  |  | - Get current position: `M114` | 
					
						
							|  |  |  | - Get firmware version: `M115` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | For further details on the above commands see the | 
					
						
							|  |  |  | [RepRap G-Code documentation](http://reprap.org/wiki/G-code). | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Klipper's goal is to support the G-Code commands produced by common | 
					
						
							|  |  |  | 3rd party software (eg, OctoPrint, Printrun, Slic3r, Cura, etc.) in | 
					
						
							|  |  |  | their standard configurations. It is not a goal to support every | 
					
						
							|  |  |  | possible G-Code command. Instead, Klipper prefers human readable | 
					
						
							|  |  |  | ["extended G-Code commands"](#extended-g-code-commands). | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## G-Code SD card commands
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Klipper also supports the following standard G-Code commands if the | 
					
						
							|  |  |  | "virtual_sdcard" config section is enabled: | 
					
						
							|  |  |  | - List SD card: `M20` | 
					
						
							|  |  |  | - Initialize SD card: `M21` | 
					
						
							|  |  |  | - Select SD file: `M23 <filename>` | 
					
						
							|  |  |  | - Start/resume SD print: `M24` | 
					
						
							|  |  |  | - Pause SD print: `M25` | 
					
						
							|  |  |  | - Set SD position: `M26 S<offset>` | 
					
						
							|  |  |  | - Report SD print status: `M27` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | # Extended G-Code Commands
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Klipper uses "extended" G-Code commands for general configuration and | 
					
						
							|  |  |  | status.  These extended commands all follow a similar format - they | 
					
						
							|  |  |  | start with a command name and may be followed by one or more | 
					
						
							|  |  |  | parameters. For example: `SET_SERVO SERVO=myservo ANGLE=5.3`. In this | 
					
						
							|  |  |  | document, the commands and parameters are shown in uppercase, however | 
					
						
							|  |  |  | they are not case sensitive. (So, "SET_SERVO" and "set_servo" both run | 
					
						
							|  |  |  | the same command.) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The following standard commands are supported: | 
					
						
							|  |  |  | - `QUERY_ENDSTOPS`: Probe the axis endstops and report if they are | 
					
						
							|  |  |  |   "triggered" or in an "open" state. This command is typically used to | 
					
						
							|  |  |  |   verify that an endstop is working correctly. | 
					
						
							| 
									
										
										
										
											2018-03-09 21:43:24 -05:00
										 |  |  | - `GET_POSITION`: Return information on the current location of the | 
					
						
							|  |  |  |   toolhead. | 
					
						
							| 
									
										
										
										
											2018-04-20 19:58:37 -04:00
										 |  |  | - `SET_GCODE_OFFSET [X=<pos>|X_ADJUST=<adjust>] | 
					
						
							|  |  |  |   [Y=<pos>|Y_ADJUST=<adjust>] [Z=<pos>|Z_ADJUST=<adjust>]`: Set a | 
					
						
							|  |  |  |   positional offset to apply to future G-Code commands. This is | 
					
						
							|  |  |  |   commonly used to virtually change the Z bed offset or to set nozzle | 
					
						
							|  |  |  |   XY offsets when switching extruders. For example, if | 
					
						
							|  |  |  |   "SET_GCODE_OFFSET Z=0.2" is sent, then future G-Code moves will | 
					
						
							|  |  |  |   have 0.2mm added to their Z height. If the X_ADJUST style parameters | 
					
						
							|  |  |  |   are used, then the adjustment will be added to any existing offset | 
					
						
							|  |  |  |   (eg, "SET_GCODE_OFFSET Z=-0.2" followed by "SET_GCODE_OFFSET | 
					
						
							|  |  |  |   Z_ADJUST=0.3" would result in a total Z offset of 0.1). | 
					
						
							| 
									
										
										
										
											2018-03-18 11:23:20 -04:00
										 |  |  | - `PID_CALIBRATE HEATER=<config_name> TARGET=<temperature> | 
					
						
							|  |  |  |   [WRITE_FILE=1]`: Perform a PID calibration test. The specified | 
					
						
							|  |  |  |   heater will be enabled until the specified target temperature is | 
					
						
							|  |  |  |   reached, and then the heater will be turned off and on for several | 
					
						
							|  |  |  |   cycles. If the WRITE_FILE parameter is enabled, then the file | 
					
						
							|  |  |  |   /tmp/heattest.txt will be created with a log of all temperature | 
					
						
							|  |  |  |   samples taken during the test. | 
					
						
							| 
									
										
										
										
											2018-04-01 15:26:25 -04:00
										 |  |  | - `SET_PRESSURE_ADVANCE [ADVANCE=<pressure_advance>] | 
					
						
							|  |  |  |   [ADVANCE_LOOKAHEAD_TIME=<pressure_advance_lookahead_time>]`: | 
					
						
							|  |  |  |   Set pressure advance parameters. | 
					
						
							| 
									
										
										
										
											2018-03-08 14:06:24 -05:00
										 |  |  | - `RESTART`: This will cause the host software to reload its config | 
					
						
							|  |  |  |   and perform an internal reset. This command will not clear error | 
					
						
							|  |  |  |   state from the micro-controller (see FIRMWARE_RESTART) nor will it | 
					
						
							|  |  |  |   load new software (see | 
					
						
							|  |  |  |   [the FAQ](FAQ.md#how-do-i-upgrade-to-the-latest-software)). | 
					
						
							|  |  |  | - `FIRMWARE_RESTART`: This is similar to a RESTART command, but it | 
					
						
							|  |  |  |   also clears any error state from the micro-controller. | 
					
						
							|  |  |  | - `STATUS`: Report the Klipper host software status. | 
					
						
							|  |  |  | - `HELP`: Report the list of available extended G-Code commands. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## Custom Pin Commands
 | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2018-03-28 15:11:10 -04:00
										 |  |  | The following command is available when an "output_pin" config section | 
					
						
							|  |  |  | is enabled: | 
					
						
							| 
									
										
										
										
											2018-03-08 14:06:24 -05:00
										 |  |  | - `SET_PIN PIN=config_name VALUE=<value>` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## Servo Commands
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The following commands are available when a "servo" config section is | 
					
						
							|  |  |  | enabled: | 
					
						
							|  |  |  | - `SET_SERVO SERVO=config_name WIDTH=<seconds>` | 
					
						
							|  |  |  | - `SET_SERVO SERVO=config_name ANGLE=<degrees>` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## Probe
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The following commands are available when a "probe" config section is | 
					
						
							|  |  |  | enabled: | 
					
						
							|  |  |  | - `PROBE`: Move the nozzle downwards until the probe triggers. | 
					
						
							|  |  |  | - `QUERY_PROBE`: Report the current status of the probe ("triggered" | 
					
						
							|  |  |  |   or "open"). | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## Delta Calibration
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The following commands are available when the "delta_calibrate" config | 
					
						
							|  |  |  | section is enabled: | 
					
						
							|  |  |  | - `DELTA_CALIBRATE`: This command will probe seven points on the bed | 
					
						
							|  |  |  |   and recommend updated endstop positions, tower angles, and radius. | 
					
						
							|  |  |  |   - `NEXT`: If manual bed probing is enabled, then one can use this | 
					
						
							|  |  |  |     command to move to the next probing point during a DELTA_CALIBRATE | 
					
						
							|  |  |  |     operation. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## Bed Tilt
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The following commands are available when the "bed_tilt" config | 
					
						
							|  |  |  | section is enabled: | 
					
						
							|  |  |  | - `BED_TILT_CALIBRATE`: This command will probe the points specified | 
					
						
							|  |  |  |   in the config and then recommend updated x and y tilt adjustments. | 
					
						
							|  |  |  |   - `NEXT`: If manual bed probing is enabled, then one can use this | 
					
						
							|  |  |  |     command to move to the next probing point during a | 
					
						
							|  |  |  |     BED_TILT_CALIBRATE operation. | 
					
						
							| 
									
										
										
										
											2018-03-10 20:20:48 -05:00
										 |  |  | 
 | 
					
						
							|  |  |  | ## Dual Carriages
 | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2018-03-28 15:11:10 -04:00
										 |  |  | The following command is available when the "dual_carriage" config | 
					
						
							| 
									
										
										
										
											2018-03-10 20:20:48 -05:00
										 |  |  | section is enabled: | 
					
						
							|  |  |  | - `SET_DUAL_CARRIAGE CARRIAGE=[0|1]`: This command will set the active | 
					
						
							|  |  |  |   carriage. It is typically invoked from the activate_gcode and | 
					
						