										 |  |  | # CANBUS Troubleshooting
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | This document provides information on troubleshooting communication | 
					
						
							|  |  |  | issues when using [Klipper with CAN bus](CANBUS.md). | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## Verify CAN bus wiring
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The first step in troubleshooting communication issues is to verify | 
					
						
							|  |  |  | the CAN bus wiring. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Be sure there are exactly two 120 Ohm [terminating | 
					
						
							|  |  |  | resistors](CANBUS.md#terminating-resistors) on the CAN bus. If the | 
					
						
							|  |  |  | resistors are not properly installed then messages may not be able to | 
					
						
							|  |  |  | be sent at all or the connection may have sporadic instability. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The CANH and CANL bus wiring should be twisted around each other. At a | 
					
						
							|  |  |  | minimum, the wiring should have a twist every few centimeters. Avoid | 
					
						
							|  |  |  | twisting the CANH and CANL wiring around power wires and ensure that | 
					
						
							|  |  |  | power wires that travel parallel to the CANH and CANL wires do not | 
					
						
							|  |  |  | have the same amount of twists. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Verify that all plugs and wire crimps on the CAN bus wiring are fully | 
					
						
							|  |  |  | secured. Movement of the printer toolhead may jostle the CAN bus | 
					
						
							|  |  |  | wiring causing a bad wire crimp or unsecured plug to result in | 
					
						
							|  |  |  | intermittent communication errors. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## Check for incrementing bytes_invalid counter
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The Klipper log file will report a `Stats` line once a second when the | 
					
						
							|  |  |  | printer is active. These "Stats" lines will have a `bytes_invalid` | 
					
						
							|  |  |  | counter for each micro-controller. This counter should not increment | 
					
						
							|  |  |  | during normal printer operation (it is normal for the counter to be | 
					
						
							|  |  |  | non-zero after a RESTART and it is not a concern if the counter | 
					
						
							|  |  |  | increments once a month or so). If this counter increments on a CAN | 
					
						
							|  |  |  | bus micro-controller during normal printing (it increments every few | 
					
						
							|  |  |  | hours or more frequently) then it is an indication of a severe | 
					
						
							|  |  |  | problem. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Incrementing `bytes_invalid` on a CAN bus connection is a symptom of | 
					
						
							|  |  |  | reordered messages on the CAN bus. There are two known causes of | 
					
						
							|  |  |  | reordered messages: | 
					
						
							|  |  |  | 1. Old versions of the popular candlight_firmware for USB CAN adapters | 
					
						
							|  |  |  |    had a bug that could cause reordered messages. If using a USB CAN | 
					
						
							|  |  |  |    adapter running this firmware then make sure to update to the | 
					
						
							|  |  |  |    latest firmware if incrementing `bytes_invalid` is observed. | 
					
						
							|  |  |  | 2. Some Linux kernel builds for embedded devices have been known to | 
					
						
							|  |  |  |    reorder CAN bus messages. It may be necessary to use an alternative | 
					
						
							|  |  |  |    Linux kernel or to use alternative hardware that supports | 
					
						
							|  |  |  |    mainstream Linux kernels that do not exhibit this problem. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Reordered messages is a severe problem that must be fixed. It will | 
					
						
							|  |  |  | result in unstable behavior and can lead to confusing errors at any | 
					
						
							|  |  |  | part of a print. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2024-04-12 14:25:05 -04:00
										 |  |  | ## Use an appropriate txqueuelen setting
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The Klipper code uses the Linux kernel to manage CAN bus traffic. By | 
					
						
							|  |  |  | default, the kernel will only queue 10 CAN transmit packets. It is | 
					
						
							|  |  |  | recommended to [configure the can0 device](CANBUS.md#host-hardware) | 
					
						
							|  |  |  | with a `txqueuelen 128` to increase that size. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | If Klipper transmits a packet and Linux has filled all of its transmit | 
					
						
							|  |  |  | queue space then Linux will drop that packet and messages like the | 
					
						
							|  |  |  | following will appear in the Klipper log: | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | Got error -1 in can write: (105)No buffer space available | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | Klipper will automatically retransmit the lost messages as part of its | 
					
						
							|  |  |  | normal application level message retransmit system. Thus, this log | 
					
						
							|  |  |  | message is a warning and it does not indicate an unrecoverable error. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | If a complete CAN bus failure occurs (such as a CAN wire break) then | 
					
						
							|  |  |  | Linux will not be able to transmit any messages on the CAN bus and it | 
					
						
							|  |  |  | is common to find the above message in the Klipper log. In this case, | 
					
						
							|  |  |  | the log message is a symptom of a larger problem (the inability to | 
					
						
							|  |  |  | transmit any messages) and is not directly related to Linux | 
					
						
							|  |  |  | `txqueuelen`. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | One may check the current queue size by running the Linux command `ip | 
					
						
							|  |  |  | link show can0`. It should report a bunch of text including the | 
					
						
							|  |  |  | snippet `qlen 128`. If one sees something like `qlen 10` then it | 
					
						
							|  |  |  | indicates the CAN device has not been properly configured. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2024-04-20 13:23:42 -04:00
										 |  |  | It is not recommended to use a `txqueuelen` significantly larger | 
					
						
							|  |  |  | than 128. A CAN bus running at a frequency of 1000000 will typically | 
					
						
							|  |  |  | take around 120us to transmit a CAN packet. Thus a queue of 128 | 
					
						
							|  |  |  | packets is likely to take around 15-20ms to drain. A substantially | 
					
						
							|  |  |  | larger queue could cause excessive spikes in message round-trip-time | 
					
						
							|  |  |  | which could lead to unrecoverable errors. Said another way, Klipper's | 
					
						
							|  |  |  | application retransmit system is more robust if it does not have to | 
					
						
							|  |  |  | wait for Linux to drain an excessively large queue of possibly stale | 
					
						
							|  |  |  | data. This is analogous to the problem of | 
					
						
							| 
									
										
										
										
											2024-04-12 14:25:05 -04:00
										 |  |  | [bufferbloat](https://en.wikipedia.org/wiki/Bufferbloat) on internet | 
					
						
							|  |  |  | routers. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Under normal circumstances Klipper may utilize ~25 queue slots per | 
					
						
							|  |  |  | MCU - typically only utilizing more slots during retransmits. | 
					
						
							|  |  |  | (Specifically, the Klipper host may transmit up to 192 bytes to each | 
					
						
							|  |  |  | Klipper MCU before receiving an acknowledgment from that MCU.) If a | 
					
						
							|  |  |  | single CAN bus has 5 or more Klipper MCUs on it, then it might be | 
					
						
							|  |  |  | necessary to increase the `txqueuelen` above the recommended value | 
					
						
							|  |  |  | of 128. However, as above, care should be taken when selecting a new | 
					
						
							|  |  |  | value to avoid excessive round-trip-time latency. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2023-05-20 20:45:49 -04:00
										 |  |  | ## Obtaining candump logs
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The CAN bus messages sent to and from the micro-controller are handled | 
					
						
							|  |  |  | by the Linux kernel. It is possible to capture these messages from the | 
					
						
							|  |  |  | kernel for debugging purposes. A log of these messages may be of use | 
					
						
							|  |  |  | in diagnostics. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The Linux [can-utils](https://github.com/linux-can/can-utils) tool | 
					
						
							|  |  |  | provides the capture software. It is typically installed on a machine | 
					
						
							|  |  |  | by running: | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | sudo apt-get update && sudo apt-get install can-utils | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Once installed, one may obtain a capture of all CAN bus messages on an | 
					
						
							|  |  |  | interface with the following command: | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | candump -tz -Ddex can0,#FFFFFFFF > mycanlog | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | One can view the resulting log file (`mycanlog` in the example above) | 
					
						
							|  |  |  | to see each raw CAN bus message that was sent and received by Klipper. | 
					
						
							|  |  |  | Understanding the content of these messages will likely require | 
					
						
							|  |  |  | low-level knowledge of Klipper's [CANBUS protocol](CANBUS_protocol.md) | 
					
						
							|  |  |  | and Klipper's [MCU commands](MCU_Commands.md). | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2023-04-14 14:55:35 -04:00
										 |  |  | ### Parsing Klipper messages in a candump log
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | One may use the `parsecandump.py` tool to parse the low-level Klipper | 
					
						
							|  |  |  | micro-controller messages contained in a candump log. Using this tool | 
					
						
							|  |  |  | is an advanced topic that requires knowledge of Klipper | 
					
						
							|  |  |  | [MCU commands](MCU_Commands.md). For example: | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | ./scripts/parsecandump.py mycanlog 108 ./out/klipper.dict | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | This tool produces output similar to the [parsedump | 
					
						
							|  |  |  | tool](Debugging.md#translating-gcode-files-to-micro-controller-commands). See | 
					
						
							|  |  |  | the documentation for that tool for information on generating the | 
					
						
							|  |  |  | Klipper micro-controller data dictionary. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | In the above example, `108` is the [CAN bus | 
					
						
							|  |  |  | id](CANBUS_protocol.md#micro-controller-id-assignment). It is a | 
					
						
							|  |  |  | hexadecimal number. The id `108` is assigned by Klipper to the first | 
					
						
							|  |  |  | micro-controller. If the CAN bus has multiple micro-controllers on it, | 
					
						
							|  |  |  | then the second micro-controller would be `10a`, the third would be | 
					
						
							|  |  |  | `10c`, and so on. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The candump log must be produced using the `-tz -Ddex` command-line | 
					
						
							|  |  |  | arguments (for example: `candump -tz -Ddex can0,#FFFFFFFF`) in order | 
					
						
							|  |  |  | to use the `parsecandump.py` tool. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2023-05-20 20:45:49 -04:00
										 |  |  | ## Using a logic analyzer on the canbus wiring
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The [Sigrok Pulseview](https://sigrok.org/wiki/PulseView) software | 
					
						
							|  |  |  | along with a low-cost | 
					
						
							|  |  |  | [logic analyzer](https://en.wikipedia.org/wiki/Logic_analyzer) can be | 
					
						
							|  |  |  | useful for diagnosing CAN bus signaling. This is an advanced topic | 
					
						
							|  |  |  | likely only of interest to experts. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | One can often find "USB logic analyzers" for under $15 (US pricing as | 
					
						
							|  |  |  | of 2023). These devices are often listed as "Saleae logic clones" or | 
					
						
							|  |  |  | as "24MHz 8 channel USB logic analyzers". | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  |  | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The above picture was taken while using Pulseview with a "Saleae | 
					
						
							|  |  |  | clone" logic analyzer. The Sigrok and Pulseview software was installed | 
					
						
							|  |  |  | on a desktop machine (also install the "fx2lafw" firmware if that is | 
					
						
							|  |  |  | packaged separately). The CH0 pin on the logic analyzer was routed to | 
					
						
							|  |  |  | the CAN Rx line, the CH1 pin was wired to the CAN Tx pin, and GND was | 
					
						
							|  |  |  | wired to GND. Pulseview was configured to only display the D0 and D1 | 
					
						
							|  |  |  | lines (red "probe" icon center top toolbar). The number of samples was | 
					
						
							|  |  |  | set to 5 million (top toolbar) and the sample rate was set to 24Mhz | 
					
						
							|  |  |  | (top toolbar). The CAN decoder was added (yellow and green "bubble | 
					
						
							|  |  |  | icon" right top toolbar). The D0 channel was labeled as RX and set to | 
					
						
							|  |  |  | trigger on a falling edge (click on black D0 label at left). The D1 | 
					
						
							|  |  |  | channel was labeled as TX (click on brown D1 label at left). The CAN | 
					
						
							|  |  |  | decoder was configured for 1Mbit rate (click on green CAN label at | 
					
						
							|  |  |  | left). The CAN decoder was moved to the top of the display (click and | 
					
						
							|  |  |  | drag green CAN label). Finally, the capture was started (click "Run" | 
					
						
							|  |  |  | at top left) and a packet was transmitted on the CAN bus (`cansend | 
					
						
							|  |  |  | can0 123#121212121212`). | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The logic analyzer provides an independent tool for capturing packets | 
					
						
							|  |  |  | and verifying bit timing. |