											2025-03-20 16:53:44 -07:00
										 |  |  | # Load Cells
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | This document describes Klipper's support for load cells. Basic load cell | 
					
						
							|  |  |  | functionality can be used to read force data and to weigh things like filament. | 
					
						
							|  |  |  | A calibrated force sensor is an important part of a load cell based probe. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## Related Documentation
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | * [load_cell Config Reference](Config_Reference.md#load_cell) | 
					
						
							|  |  |  | * [load_cell G-Code Commands](G-Codes.md#load_cell) | 
					
						
							|  |  |  | * [load_cell Status Reference](Status_Reference.md#load_cell) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## Using `LOAD_CELL_DIAGNOSTIC`
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | When you first connect a load cell its good practice to check for issues by | 
					
						
							|  |  |  | running `LOAD_CELL_DIAGNOSTIC`. This tool collects 10 seconds of data from the | 
					
						
							|  |  |  | load cell and resport statistics: | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | $ LOAD_CELL_DIAGNOSTIC | 
					
						
							|  |  |  | // Collecting load cell data for 10 seconds... | 
					
						
							|  |  |  | // Samples Collected: 3211 | 
					
						
							|  |  |  | // Measured samples per second: 332.0 | 
					
						
							|  |  |  | // Good samples: 3211, Saturated samples: 0, Unique values: 900 | 
					
						
							|  |  |  | // Sample range: [4.01% to 4.02%] | 
					
						
							|  |  |  | // Sample range / sensor capacity: 0.00524% | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Things you can check with this data: | 
					
						
							| 
									
										
										
										
											2024-09-15 19:12:25 -07:00
										 |  |  | 
 | 
					
						
							| 
									
										
										
										
											2025-03-20 16:53:44 -07:00
										 |  |  | * The configured sample rate of the sensor should be close to the 'Measured | 
					
						
							| 
									
										
										
										
											2024-09-15 19:12:25 -07:00
										 |  |  |   samples per second' value. If it is not you may have a configuration or wiring | 
					
						
							|  |  |  |   issue. | 
					
						
							| 
									
										
										
										
											2025-03-20 16:53:44 -07:00
										 |  |  | * 'Saturated samples' should be 0. If you have saturated samples it means the | 
					
						
							| 
									
										
										
										
											2024-09-15 19:12:25 -07:00
										 |  |  |   load sell is seeing more force than it can measure. | 
					
						
							| 
									
										
										
										
											2025-03-20 16:53:44 -07:00
										 |  |  | * 'Unique values' should be a large percentage of the 'Samples | 
					
						
							| 
									
										
										
										
											2024-09-15 19:12:25 -07:00
										 |  |  |   Collected' value. If 'Unique values' is 1 it is very likely a wiring issue. | 
					
						
							| 
									
										
										
										
											2025-03-20 16:53:44 -07:00
										 |  |  | * Tap or push on the sensor while `LOAD_CELL_DIAGNOSTIC` runs. If | 
					
						
							| 
									
										
										
										
											2024-09-15 19:12:25 -07:00
										 |  |  |   things are working correctly ths should increase the 'Sample range'. | 
					
						
							| 
									
										
										
										
											2025-03-20 16:53:44 -07:00
										 |  |  | 
 | 
					
						
							|  |  |  | ## Calibrating a Load Cell
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Load cells are calibrated using the `LOAD_CELL_CALIBRATE` command. This is an | 
					
						
							|  |  |  | interactive calibration utility that walks you though a 3 step process: | 
					
						
							| 
									
										
										
										
											2024-09-15 19:12:25 -07:00
										 |  |  | 
 | 
					
						
							| 
									
										
										
										
											2025-03-20 16:53:44 -07:00
										 |  |  | 1. First use the `TARE` command to establish the zero force value. This is the | 
					
						
							| 
									
										
										
										
											2024-09-15 19:12:25 -07:00
										 |  |  |    `reference_tare_counts` config value. | 
					
						
							| 
									
										
										
										
											2025-03-20 16:53:44 -07:00
										 |  |  | 2. Next you apply a known load or force to the load cell and run the | 
					
						
							| 
									
										
										
										
											2024-09-15 19:12:25 -07:00
										 |  |  |    `CALIBRATE GRAMS=nnn` command. From this the `counts_per_gram` value is | 
					
						
							|  |  |  |    calculated. See [the next section](#applying-a-known-force-or-load) for some | 
					
						
							|  |  |  |    suggestions on how to do this. | 
					
						
							| 
									
										
										
										
											2025-03-20 16:53:44 -07:00
										 |  |  | 3. Finally, use the `ACCEPT` command to save the results. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | You can cancel the calibration process at any time with `ABORT`. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ### Applying a Known Force or Load
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The `CALIBRATE GRAMS=nnn` step can be accomplished in a number of ways. If your | 
					
						
							|  |  |  | load cell is under a platform like a bed or filament holder it might be easiest | 
					
						
							|  |  |  | to put a known mass on the platform. E.g. you could use a couple of 1KG filament | 
					
						
							|  |  |  | spools. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | If your load cell is in the printer's toolhead a different approach is easier. | 
					
						
							|  |  |  | Put a digital scale on the printers bed and gently lower the toolhead onto the | 
					
						
							|  |  |  | scale (or raise the bed into the toolhead if your bed moves). You may be able to | 
					
						
							|  |  |  | do this using the `FORCE_MOVE` command. But more likely you will have to | 
					
						
							|  |  |  | manually moving the z axis with the motors off until the toolhead presses on the | 
					
						
							|  |  |  | scale. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | A good calibration force would ideally be a large percentage of the load cell's | 
					
						
							|  |  |  | rated capacity. E.g. if you have a 5Kg load cell you would ideally calibrate it | 
					
						
							|  |  |  | with a 5kg mass. This might work well with under-bed sensors that have to | 
					
						
							|  |  |  | support a lot of weight. For toolhead probes this may not be a load that your | 
					
						
							|  |  |  | printer bed or toolhead can tolerate without damage. Do try to use at least 1Kg | 
					
						
							|  |  |  | of force, most printers should tolerate this without issue. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | When calibrating make careful note of the values reported: | 
					
						
							| 
									
										
										
										
											2024-09-15 19:12:25 -07:00
										 |  |  | 
 | 
					
						
							| 
									
										
										
										
											2025-03-20 16:53:44 -07:00
										 |  |  | ``` | 
					
						
							|  |  |  | $ CALIBRATE GRAMS=555 | 
					
						
							|  |  |  | // Calibration value: -2.78% (-59803108), Counts/gram: 73039.78739, | 
					
						
							|  |  |  | Total capacity: +/- 29.14Kg | 
					
						
							|  |  |  | ``` | 
					
						
							| 
									
										
										
										
											2024-09-15 19:12:25 -07:00
										 |  |  | 
 | 
					
						
							| 
									
										
										
										
											2025-03-20 16:53:44 -07:00
										 |  |  | The `Total capacity` should be close to the theoretical rating of the load cell | 
					
						
							|  |  |  | based on the sensor's capacity. If it is much larger you could have used a | 
					
						
							|  |  |  | higher gain setting in the sensor or a more sensitive load cell. This isn't as | 
					
						
							|  |  |  | critical for 32bit and 24bit sensors but is much more critical for low bit width | 
					
						
							|  |  |  | sensors. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## Reading Force Data
 | 
					
						
							|  |  |  | Force data can be read with a GCode command: | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | LOAD_CELL_READ | 
					
						
							|  |  |  | // 10.6g (1.94%) | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Data is also continuously read and can be consumed from the load_cell printer | 
					
						
							|  |  |  | object in a macro: | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | {% set grams = printer.load_cell.force_g %} | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | This provides an average force over the last 1 second, similar to how | 
					
						
							|  |  |  | temperature sensors work. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## Taring a Load Cell
 | 
					
						
							|  |  |  | Taring, sometimes called zeroing, sets the current weight reported by the | 
					
						
							|  |  |  | load_cell to 0. This is useful for measuring relative to a known weight. e.g. | 
					
						
							|  |  |  | when measuring a filament spool, using `LOAD_CELL_TARE` sets the weight to 0. | 
					
						
							|  |  |  | Then as filament is printed the load_cell will report the weight of the | 
					
						
							|  |  |  | filament used. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | LOAD_CELL_TARE | 
					
						
							|  |  |  | // Load cell tare value: 5.32% (445903) | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The current tare value is reported in the printers status and can be read in | 
					
						
							|  |  |  | a macro: | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | {% set tare_counts = printer.load_cell.tare_counts %} | 
					
						
							|  |  |  | ``` | 
					
						
							| 
									
										
										
										
											2024-09-15 19:12:25 -07:00
										 |  |  | 
 | 
					
						
							|  |  |  | # Load Cell Probes
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## Related Documentation
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | * [load_cell_probe Config Reference](Config_Reference.md#load_cell_probe) | 
					
						
							|  |  |  | * [load_cell_probe G-Code Commands](G-Codes.md#load_cell_probe) | 
					
						
							|  |  |  | * [load_cell_probe Statuc Reference](Status_Reference.md#load_cell_probe) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## Load Cell Probe Safety
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Because load cells are a direct nozzle contact probe there is a risk of | 
					
						
							|  |  |  | damage to your printer if too much force is used. The load cell probing system | 
					
						
							|  |  |  | includes a number of safety checks that try to keep your machine safe from | 
					
						
							|  |  |  | excessive force to the toolhead. It's important to understand what they are | 
					
						
							|  |  |  | and how they work as you can defeat most of them with poorly chosen config | 
					
						
							|  |  |  | values. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | #### Calibration Check
 | 
					
						
							|  |  |  | Every time a homing move starts, load_cell_probe checks | 
					
						
							|  |  |  | that the load_cell is calibrated. If not it will stop the move with an error: | 
					
						
							|  |  |  | `!! Load Cell not calibrated`. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | #### `counts_per_gram`
 | 
					
						
							|  |  |  | This setting is used to convert raw sensor counts into grams. All the safety | 
					
						
							|  |  |  | limits are in gram units for your convenience. If the `counts_per_gram` | 
					
						
							|  |  |  | setting is not accurate you can easily exceed the safe force on the toolhead. | 
					
						
							|  |  |  | You should never guess this value. Use `LOAD_CELL_CALIBRATE` to find your load | 
					
						
							|  |  |  | cells actual `counts_per_gram`. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | #### `trigger_force`
 | 
					
						
							|  |  |  | This is the force in grams that triggers the endstop to halt the homing move. | 
					
						
							|  |  |  | When a homing move starts the endstop tares itself with the current reading | 
					
						
							|  |  |  | from the load cell. `trigger_force` is measured from that tare value. There is | 
					
						
							|  |  |  | always some overshoot of this value when the probe collides with the bed, | 
					
						
							|  |  |  | so be conservative. e.g. a setting of 100g could result in 350g of peak force | 
					
						
							|  |  |  | before the toolhead stops. This overshoot will increase with faster probing | 
					
						
							|  |  |  | `speed`, a low ADC sample rate or [multi MCU homing](Multi_MCU_Homing.md). | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | #### `reference_tare_counts`
 | 
					
						
							|  |  |  | This is the baseline tare value that is set by `LOAD_CELL_CALIBRATE`. | 
					
						
							|  |  |  | This value works with `force_safety_limit` to limit the maximum force on the | 
					
						
							|  |  |  | toolhead. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | #### `force_safety_limit`
 | 
					
						
							|  |  |  | This is the maximum absolute force, relative to `reference_tare_counts`, | 
					
						
							|  |  |  | that the probe will allow while homing or probing. If the MCU sees this | 
					
						
							|  |  |  | force exceeded it will shut down the printer with the error `!! Load cell | 
					
						
							|  |  |  | endstop: too much force!`. There are a number of ways this can be triggered: | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The first risk this protects against is picking too large of a value for | 
					
						
							|  |  |  | `drift_filter_cutoff_frequency`. This can cause the drift filter to filter out | 
					
						
							|  |  |  | a probe event and continue the homing move. If this happens the | 
					
						
							|  |  |  | `force_safety_limit` acts as a backup protection. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The second problem is probing repeatedly in one place. Klipper does not retract | 
					
						
							|  |  |  | the probe when doing a single `PROBE` command. This can result | 
					
						
							|  |  |  | in force applied to the toolhead at the end of a probing cycle. Because | 
					
						
							|  |  |  | external forces can vary greatly between probing locations, | 
					
						
							|  |  |  | `load_cell_probe` performs a tare before beginning each probe. If you repeat | 
					
						
							|  |  |  | the `PROBE` command, load_cell_probe will tare the endstop at the current force. | 
					
						
							|  |  |  | Multiple cycles of this will result in ever-increasing force on the toolhead. | 
					
						
							|  |  |  | `force_safety_limit` stops this cycle from running out of control. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Another way this run-away can happen is damage to a strain gauge. If the metal | 
					
						
							|  |  |  | part is permanently bent it wil change the `reference_tare_counts` of the | 
					
						
							|  |  |  | device. This puts the starting tare value much closer to the limit making it | 
					
						
							|  |  |  | more likely to be violated. You want to be notified if this is happening | 
					
						
							|  |  |  | because your hardware has been permanently damaged. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The final way this can be triggered is due to temperature changes. If your | 
					
						
							|  |  |  | strain gauges are heated their `reference_tare_counts` may be very different | 
					
						
							|  |  |  | at ambient temperature vs operating temperature. In this case you may need | 
					
						
							|  |  |  | to increase the `force_safety_limit` to allow for thermal changes. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | #### Load Cell Endstop Watchdog Task
 | 
					
						
							|  |  |  | When homing the load_cell_endstop starts a task on the MCU to trac | 
					
						
							|  |  |  | measurements arriving from the sensor. If the sensor fails to send | 
					
						
							|  |  |  | measurements for 2 sample periods the watchdog will shut down the printer | 
					
						
							|  |  |  | with an error `!! LoadCell Endstop timed out waiting on ADC data`. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | If this happens, the most likely cause is a fault from the ADC. Inadequate | 
					
						
							|  |  |  | grounding of your printer can be the root cause. The frame, power supply | 
					
						
							|  |  |  | case and pint bed should all be connected to ground. You may need to ground | 
					
						
							|  |  |  | the frame in multiple places. Anodized aluminum extrusions do not conduct | 
					
						
							|  |  |  | electricity well. You might need to sand the area where the grounding wire | 
					
						
							|  |  |  | is attached to make good electrical contact. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## Load Cell Probe Setup
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | This section covers the process for commissioning a load cell probe. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ### Verify the Load Cell First
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | A `[load_cell_probe]` is also a `[load_cell]` and G-code commands related to | 
					
						
							|  |  |  | `[load_cell]` work with `[load_cell_probe]`. Before attempting to use a load | 
					
						
							|  |  |  | cell probe, follow the directions for | 
					
						
							|  |  |  | [calibrating the load cell](Load_Cell.md#calibrating-a-load-cell) with | 
					
						
							|  |  |  | `CALIBRATE_LOAD_CELL` and checking its operation with `LOAD_CELL_DIAGNOSTIC`. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ### Verify Probe Operation With LOAD_CELL_TEST_TAP
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Use the command `LOAD_CELL_TEST_TAP` to test the operation of the load cell | 
					
						
							|  |  |  | probe before actually trying to probe with it. This command detects taps, | 
					
						
							|  |  |  | just like the PROBE command, but it does not move the z axis. By default, it | 
					
						
							|  |  |  | listens for 3 taps before ending the test. You have 30 seconds to do each | 
					
						
							|  |  |  | tap, if no taps are detected the command will time out. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | If this test fails, check your configuration and `LOAD_CELL_DIAGNOSTIC` | 
					
						
							|  |  |  | carefully to look for issues. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Load cell probes don't support the `QUERY_ENDSTOPS` or `QUERY_PROBE` | 
					
						
							|  |  |  | commands. Use `LOAD_CELL_TEST_TAP` for testing functionality before probing. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ### Homing Macros
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Load cell probe is not an endstop and doesn't support `endstop: | 
					
						
							|  |  |  | prove:z_virtual_endstop`. For the time being you'll need to configure your z | 
					
						
							|  |  |  | axis with an MCU pin as its endstop. You won't actually be using the pin but | 
					
						
							|  |  |  | for the time being you have to configure something. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | To home the axis with just the probe you need to set up a custom homing | 
					
						
							|  |  |  | macro. This requires setting up | 
					
						
							|  |  |  | [homing_override](Config_Reference.md#homing_override). | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Here is a simple macro that can accomplish this. Note that the | 
					
						
							|  |  |  | `_HOME_Z_FROM_LAST_PROBE` macro has to be separate because of the way macros | 
					
						
							|  |  |  | work. The sub-call is needed so that the `_HOME_Z_FROM_LAST_PROBE` macro can | 
					
						
							|  |  |  | see the result of the probe in `printer.probe.last_z_result`. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ```gcode | 
					
						
							|  |  |  | [gcode_macro _HOME_Z_FROM_LAST_PROBE] | 
					
						
							|  |  |  | gcode: | 
					
						
							|  |  |  |     {% set z_probed = printer.probe.last_z_result %} | 
					
						
							|  |  |  |     {% set z_position = printer.toolhead.position[2] %} | 
					
						
							|  |  |  |     {% set z_actual = z_position - z_probed %} | 
					
						
							|  |  |  |     SET_KINEMATIC_POSITION Z={z_actual} | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | [gcode_macro _HOME_Z] | 
					
						
							|  |  |  | gcode: | 
					
						
							|  |  |  |     SET_GCODE_OFFSET Z=0  # load cell probes dont need a Z offset | 
					
						
							|  |  |  |     # position toolhead for homing Z, edit for your printers size | 
					
						
							|  |  |  |     #G90  # absolute move | 
					
						
							|  |  |  |     #G1 Y50 X50 F{5 * 60}  # move to X/Y position for homing | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  |     # soft home the z axis to its limit so it can be moved: | 
					
						
							|  |  |  |     SET_KINEMATIC_POSITION Z={printer.toolhead.axis_maximum[2]} | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  |     # Fast approach and tap | 
					
						
							|  |  |  |     PROBE PROBE_SPEED={5 * 60}  # override the speed for faster homing | 
					
						
							|  |  |  |     _HOME_Z_FROM_LAST_PROBE | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  |     # lift z to 2mm | 
					
						
							|  |  |  |     G91  # relative move | 
					
						
							|  |  |  |     G1 Z2 F{5 * 60} | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  |     # probe at standard speed | 
					
						
							|  |  |  |     PROBE | 
					
						
							|  |  |  |     _HOME_Z_FROM_LAST_PROBE | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  |     # lift z to 10mm for clearance | 
					
						
							|  |  |  |     G91  # relative move | 
					
						
							|  |  |  |     G1 Z10 F{5 * 60} | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ### Suggested Probing Temperature
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Currently, we suggest keeping the nozzle temperature below the level that causes | 
					
						
							|  |  |  | the filament to ooze while homing and probing. 140C is a good starting | 
					
						
							|  |  |  | point. This temperature is also low enough not to scar PEI build surfaces. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Fouling of the nozzle and the print bed due to oozing filament is the #1 source | 
					
						
							|  |  |  | of probing error with the load cell probe. Klipper does not yet have a universal | 
					
						
							|  |  |  | way to detect poor quality taps due to filament ooze. The existing code may | 
					
						
							|  |  |  | decide that a tap is valid when it is of poor quality. Classifying these poor | 
					
						
							|  |  |  | quality taps is an area of active research. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Klipper also lacks support for re-locating a probe point if the | 
					
						
							|  |  |  | location has become fouled by filament ooze. Modules like `quad_gantry_level` | 
					
						
							|  |  |  | will repeatedly probe the same coordinates even if a probe previously failed | 
					
						
							|  |  |  | there. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Give the above it is strongly suggested not to probe at printing temperatures. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ### Hot Nozzle Protection
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The Voron project has a great macro for protecting your print surface from the | 
					
						
							|  |  |  | hot nozzle. See [Voron Tap's | 
					
						
							|  |  |  | `activate_gcode`](https://github.com/VoronDesign/Voron-Tap/blob/main/config/tap_klipper_instructions.md) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | It is highly suggested to add something like this to your config. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ### Nozzle Cleaning
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Before probing the nozzle should be clean. You could do this manually before | 
					
						
							|  |  |  | every print. You can also implement a nozzle scrubber and automate the process. | 
					
						
							|  |  |  | Here is a suggested sequence: | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | 1. Wait for the nozzle to heat up to probing temp (e.g. `M109 S140`) | 
					
						
							|  |  |  | 1. Home the machine (`G28`) | 
					
						
							|  |  |  | 1. Scrub the nozzle on a brush | 
					
						
							|  |  |  | 1. Heat soak the print bed | 
					
						
							|  |  |  | 1. Perform probing tasks: QGL, bed mesh etc. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ### Temperature Compensation for Nozzle Growth
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | If you are probing at a safe temperature, the nozzle will expand after | 
					
						
							|  |  |  | heating to printing temperatures. This will cause the nozzle to get longer | 
					
						
							|  |  |  | and closer to the print surface. You can compensate for this with | 
					
						
							|  |  |  | [[z_thermal_adjust]](Config_Reference.md#z_thermal_adjust). This adjustment will | 
					
						
							|  |  |  | work across a range of printing | 
					
						
							|  |  |  | temperatures from PLA to PC. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | #### Calculating the `temp_coeff` for `[z_thermal_adjust]`
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The easiest way to do this is to measure at 2 different temperatures. | 
					
						
							|  |  |  | Ideally these should be the upper and lower limits of the printing | 
					
						
							|  |  |  | temperature range. E.g. 180C and 290C. You can perform a `PROBE_ACCURACY` at | 
					
						
							|  |  |  | both temperatures and then calculate the difference of the `average z` at both. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The adjustment value is the change in nozzle length divided by the change in | 
					
						
							|  |  |  | temperature. e.g. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | temp_coeff = -0.05 / (290 - 180) = -0.00045455 | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The expected result is a negative number. Positive values for `temp_coeff` move | 
					
						
							|  |  |  | the nozzle closer to the bed and negative values move it further away. | 
					
						
							|  |  |  | Expect to have to move the nozzle further away as it gets longer when hot. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | #### Configure `[z_thermal_adjust]`
 | 
					
						
							|  |  |  | Set up z_thermal_adjust to reference the `extruder` as the source of temperature | 
					
						
							|  |  |  | data. E.g.: | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | [z_thermal_adjust nozzle] | 
					
						
							|  |  |  | temp_coeff=-0.00045455 | 
					
						
							|  |  |  | sensor_type: temperature_combined | 
					
						
							|  |  |  | sensor_list: extruder | 
					
						
							|  |  |  | combination_method: max | 
					
						
							|  |  |  | min_temp: 0 | 
					
						
							|  |  |  | max_temp: 400 | 
					
						
							|  |  |  | max_z_adjustment: 0.1 | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## Continuous Tare Filters for Toolhead Load Cells
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Klipper implements a configurable IIR filter on the MCU to provide continuous | 
					
						
							|  |  |  | tareing of the load cell while probing. Continuous taring means the 0 value | 
					
						
							|  |  |  | moves with drift caused by external factors like bowden tubes and thermal | 
					
						
							|  |  |  | changes. This is aimed at toolhead sensors and moving beds that experience lots | 
					
						
							|  |  |  | of external forces that change while probing. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ### Installing SciPy
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The filtering code uses the excellent [SciPy](https://scipy.org/) library to | 
					
						
							|  |  |  | compute the filter coefficients based on the values your enter into the config. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Pre-compiled SciPi builds are available for Python 3 on 32 bit Raspberry Pi | 
					
						
							|  |  |  | systems. 32 bit + Python 3 is strongly recommended because it will streamline | 
					
						
							|  |  |  | your installation experience. It does work with Python 2 but installation can | 
					
						
							|  |  |  | take 30+ minutes and require installing additional tools. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ```bash | 
					
						
							|  |  |  | ~/klippy-env/bin/pip install scipy | 
					
						
							|  |  |  | ``` | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ### Filter Workbench
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The filter parameters should be selected based on drift seen on the printer | 
					
						
							|  |  |  | during normal operation. A Jupyter notebook is provided in scripts, | 
					
						
							|  |  |  | [filter_workbench.ipynb](../scripts/filter_workbench.ipynb), to perform a | 
					
						
							|  |  |  | detailed investigation with real captured data and FFTs. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ### Filtering Suggestions
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | For those just trying to get a filter working follow these suggestions: | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | * The only essential option is `drift_filter_cutoff_frequency`. A conservative | 
					
						
							|  |  |  |   starting value is `0.5`Hz. Prusa shipped the MK4 with a setting of `0.8`Hz and | 
					
						
							|  |  |  |   the XL with `11.2`Hz. This is probably a safe range to experiment with. This | 
					
						
							|  |  |  |   value should be increased only until normal drift due to bowden tube force is | 
					
						
							|  |  |  |   eliminated. Setting this value too high will result in slow triggering and | 
					
						
							|  |  |  |   excess force going through the toolhead. | 
					
						
							|  |  |  | * Keep `trigger_force` low. The default is `75`g. The drift filter keeps the | 
					
						
							|  |  |  |   internal grams value very close to 0 so a large trigger force is not needed. | 
					
						
							|  |  |  | * Keep `force_safety_limit` to a conservative value. The default value is 2Kg | 
					
						
							|  |  |  |   and should keep your toolhead safe while experimenting. If you hit this limit | 
					
						
							|  |  |  |   the `drift_filter_cutoff_frequency` value may be too high. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ## Suggestions for Load Cell Tool Boards
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | This section covers suggestions for those developing toolhead boards that want | 
					
						
							|  |  |  | to support [load_cell_probe] | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ### ADC Sensor Selection & Board Development Hints
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Ideally a sensor would meet these criteria: | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | * At least 24 bits wide | 
					
						
							|  |  |  | * Use SPI communications | 
					
						
							|  |  |  | * Has a pin can be used to indicate sample ready without SPI communications. | 
					
						
							|  |  |  |   This is often called the "data ready" or "DRDY" pin. Checking a pin is much | 
					
						
							|  |  |  |   faster than running an SPI query. | 
					
						
							|  |  |  | * Has a programmable gain amplifier gain setting of 128. This should eliminate | 
					
						
							|  |  |  |   the need for a separate amplifier. | 
					
						
							|  |  |  | * Indicates via SPI if the sensor has been reset. Detecting resets avoids | 
					
						
							|  |  |  |   timing errors in homing and using noisy data at startup. It can also help | 
					
						
							|  |  |  |   users | 
					
						
							|  |  |  |   track down wiring and grounding issues. | 
					
						
							|  |  |  | * A selectable sample rate between 350Hz and 2Khz. Very high sample rates don't | 
					
						
							|  |  |  |   turn out to be beneficial in our 3D printers because they produce so much | 
					
						
							|  |  |  |   noise | 
					
						
							|  |  |  |   when moving fast. Sample rates below 250Hz will require slower probing speeds. | 
					
						
							|  |  |  |   They also increase the force on the toolhead due to longer delays between | 
					
						
							|  |  |  |   measurements. E.g. a 500Hz sensor moving at 5mm/s has the same safety factor | 
					
						
							|  |  |  |   as | 
					
						
							|  |  |  |   a 100Hz sensor moving at only 1mm/s. | 
					
						
							|  |  |  | * If designing for under-bed applications, and you want to sense multiple load | 
					
						
							|  |  |  |   cells, use a chip that can sample all of its inputs simultaneously. Multiplex | 
					
						
							|  |  |  |   ADCs that require switching channels have a settling of several samples after | 
					
						
							|  |  |  |   each channel switch making them unsuitable for probing applications. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Implementing support for a new sensor chip is not particularly difficult with | 
					
						
							|  |  |  | Klipper's `bulk_sensor` and `load_cell_endstop` infrastructure. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ### 5V Power Filtering
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | It is strongly suggested to use larger capacitors than specified by the ADC chip | 
					
						
							|  |  |  | manufacturer. ADC chips are usually targeted at low noise environments, like | 
					
						
							|  |  |  | battery powered devices. Sensor manufacturers suggested application notes | 
					
						
							|  |  |  | generally assume a quiet power supply. Treat their suggested capacitor values as | 
					
						
							|  |  |  | minimums. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | 3D printers put huge amounts of noise onto the 5V bus and this can ruin the | 
					
						
							|  |  |  | sensor's accuracy. Test the sensor on the board with a typical 3D printer power | 
					
						
							|  |  |  | supply and active stepper drivers before deciding on smoothing capacitor sizes. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ### Grounding & Ground Planes
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Analog ADC chips contain components that are very vulnerable to noise and | 
					
						
							|  |  |  | ESD. A large ground plane on the first board layer under the chip can help with | 
					
						
							|  |  |  | noise. Keep the chip away from power sections and DC to DC converters. The board | 
					
						
							|  |  |  | should have proper grounding back to the DC supply. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | ### HX711 and HX717 Notes
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | This sensor is popular because of its low cost and availability in the | 
					
						
							|  |  |  | supply chain. However, this is a sensor with some drawbacks: | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | * The HX71x sensors use bit-bang communication which has a high overhead on the | 
					
						
							|  |  |  |   MCU. Using a sensor that communicates via SPI would save resources on the tool | 
					
						
							|  |  |  |   board's CPU. | 
					
						
							|  |  |  | * The HX71x lacks a way to communicate reset events to the MCU. Klipper detects | 
					
						
							|  |  |  |   resets with a timing heuristic but this is not ideal. Resets indicate a | 
					
						
							|  |  |  |   problem with wiring or grounding. | 
					
						
							|  |  |  | * For probing applications the HX717 version is strongly preferred because | 
					
						
							|  |  |  |   of its higher sample rate (320 vs 80). Probing speed on the HX711 should be | 
					
						
							|  |  |  |   limited to less than 2mm/s. | 
					
						
							|  |  |  | * The sample rate on the HX71x cannot be set from klipper's config. If you have | 
					
						
							|  |  |  |   the 10SPS version of the sensor (which is widely distributed) it needs to | 
					
						
							|  |  |  |   be physically re-wired to run at 80SPS. |